Institutional Tuberculosis Transmission. Controlled Trial of Upper Room Ultraviolet Air Disinfection: A Basis for New Dosing Guidelines.

نویسندگان

  • Matsie Mphaphlele
  • Ashwin S Dharmadhikari
  • Paul A Jensen
  • Stephen N Rudnick
  • Tobias H van Reenen
  • Marcello A Pagano
  • Wilhelm Leuschner
  • Tim A Sears
  • Sonya P Milonova
  • Martie van der Walt
  • Anton C Stoltz
  • Karin Weyer
  • Edward A Nardell
چکیده

RATIONALE Transmission is driving the global tuberculosis epidemic, especially in congregate settings. Worldwide, natural ventilation is the most common means of air disinfection, but it is inherently unreliable and of limited use in cold climates. Upper room germicidal ultraviolet (UV) air disinfection with air mixing has been shown to be highly effective, but improved evidence-based dosing guidelines are needed. OBJECTIVES To test the efficacy of upper room germicidal air disinfection with air mixing to reduce tuberculosis transmission under real hospital conditions, and to define the application parameters responsible as a basis for proposed new dosing guidelines. METHODS Over an exposure period of 7 months, 90 guinea pigs breathed only untreated exhaust ward air, and another 90 guinea pigs breathed only air from the same six-bed tuberculosis ward on alternate days when upper room germicidal air disinfection was turned on throughout the ward. MEASUREMENTS AND MAIN RESULTS The tuberculin skin test conversion rates (>6 mm) of the two chambers were compared. The hazard ratio for guinea pigs in the control chamber converting their skin test to positive was 4.9 (95% confidence interval, 2.8-8.6), with an efficacy of approximately 80%. CONCLUSIONS Upper room germicidal UV air disinfection with air mixing was highly effective in reducing tuberculosis transmission under hospital conditions. These data support using either a total fixture output (rather than electrical or UV lamp wattage) of 15-20 mW/m(3) total room volume, or an average whole-room UV irradiance (fluence rate) of 5-7 μW/cm(2), calculated by a lighting computer-assisted design program modified for UV use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety of upper-room ultraviolet germicidal air disinfection for room occupants: results from the Tuberculosis Ultraviolet Shelter Study.

OBJECTIVES We evaluated the safety of room occupants in the Tuberculosis Ultraviolet Shelter Study (TUSS), a double-blind, placebo-controlled field trial of upper-room ultraviolet germicidal irradiation (UVGI) at 14 homeless shelters in six U.S. cities from 1997 to 2004. METHODS Data collection involved administering questionnaires regarding eye and skin irritation to a total of 3,611 staff a...

متن کامل

UVGI Design Basics for Air and Surface Disinfection

Lethal to microorganisms, ultraviolet radiation in the range of 2250 to 3020 angstroms is used in a variety of disinfection applications, a process referred to as ultraviolet germicidal irradiation (UVGI). Since the first UVGI system was successfully implemented for disinfecting the municipal water system in Marseilles, France, in 1909, the disinfection of medical equipment using UVGI has been ...

متن کامل

Monitoring human exposures to upper-room germicidal ultraviolet irradiation.

After decades of neglect, the resurgence of tuberculosis in the United States between 1985 and 1992 renewed interest in the use of upper room ultraviolet germicidal irradiation to interrupt the transmission of airborne infections. More recently the bioterrorism threat and the appearance of new pathogens with the potential for airborne spread, such as severe acute respiratory syndrome (SARS), ha...

متن کامل

Upper-Room Ultraviolet Light and Negative Air Ionization to Prevent Tuberculosis Transmission

BACKGROUND Institutional tuberculosis (TB) transmission is an important public health problem highlighted by the HIV/AIDS pandemic and the emergence of multidrug- and extensively drug-resistant TB. Effective TB infection control measures are urgently needed. We evaluated the efficacy of upper-room ultraviolet (UV) lights and negative air ionization for preventing airborne TB transmission using ...

متن کامل

The history of ultraviolet germicidal irradiation for air disinfection.

Public health concerns such as multi- and extensive drug-resistant tuberculosis, bioterrorism, pandemic influenza, and severe acute respiratory syndrome have intensified efforts to prevent transmission of infections that are completely or partially airborne using environmental controls. One such control, ultraviolet germicidal irradiation (UVGI), has received renewed interest after decades of u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of respiratory and critical care medicine

دوره 192 4  شماره 

صفحات  -

تاریخ انتشار 2015