Clinical results using the Holladay 2 intraocular lens power formula.
نویسنده
چکیده
PURPOSE To analyze the accuracy of the Holladay 2 formula, which has been proposed as an improvement over the original Holladay formula. METHODS This retrospective analysis comprised 317 eyes operated on by 1 surgeon using 1 technique and 1 intraocular lens style in a specialty practice. Because the Holladay 2 formula has yet to be published, its accuracy can only be analyzed using the commercially available Holladay IOL Consultant computer program to compare it to the Holladay 1, Hoffer Q, and SRK/T formulas. Defined axial length ranges were analyzed individually. RESULTS A lower mean absolute error (MAE) trend was found for the average length eye (22.0 to 24.5 mm) by the Holladay 1 and Hoffer Q formulas. For short eyes (< 22.0 mm), the Hoffer Q and Holladay 2 perform better. The SRK/T consistently showed a trend toward the lowest MAE in all long eyes (>24.5 mm) as well as the subdivisions of medium long (24.5 to 26.0 mm) and very long (>26.0 mm). The Holladay 2 trended toward the least accurate (MAE) of the 4 formulas in all ranges of axial length except the shortest and the very longest. It appears to perform poorer in average and medium long eyes. CONCLUSIONS Although the Holladay 2 formula has improved its MAE accuracy in short eyes, it was not more accurate than the Hoffer Q. The changes made in the formula to effect this improvement in MAE seem to have sacrificed the accuracy of the original Holladay formula in eyes with average and medium long axial lengths.
منابع مشابه
Comparison of intraocular lens power calculation methods in eyes that have undergone laser-assisted in-situ keratomileusis.
PURPOSE To compare methods of calculating intraocular lens (IOL) power for cataract surgery in eyes that have undergone myopic laser-assisted in-situ keratomileusis (LASIK). METHODS Eleven eyes of eight patients who had previously undergone myopic LASIK (amount of LASIK correction, -5.50 +/- 2.61 D (SD); range, -8.78 to -2.38 D) and subsequently phacoemulsification with implantation of the SA...
متن کاملPredictability of intraocular lens power calculation formulae in infantile eyes with unilateral congenital cataract: results from the Infant Aphakia Treatment Study.
PURPOSE To compare accuracy of intraocular lens (IOL) power calculation formulae in infantile eyes with primary IOL implantation. DESIGN Comparative case series. METHODS The Hoffer Q, Holladay 1, Holladay 2, Sanders-Retzlaff-Kraff (SRK) II, and Sanders-Retzlaff-Kraff theoretic (SRK/T) formulae were used to calculate predicted postoperative refraction for eyes that received primary IOL impla...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملAccuracy of Scheimpflug Holladay equivalent keratometry readings after corneal refractive surgery.
PURPOSE To determine the accuracy of Pentacam Scheimpflug system Holladay equivalent keratometry (K) readings (EKRs) in calculating intraocular lens (IOL) power after corneal refractive surgery, including laser in situ keratomileusis (LASIK), photorefractive keratectomy (PRK), and radial keratotomy (RK). SETTING Jules Stein Eye Institute, David Geffen School of Medicine at University of Calif...
متن کاملAccuracy of Intraocular Lens Power Calculation Formulas for Highly Myopic Eyes.
Purpose. To evaluate and compare the accuracy of different intraocular lens (IOL) power calculation formulas for eyes with an axial length (AL) greater than 26.00 mm. Methods. This study reviewed 407 eyes of 219 patients with AL longer than 26.0 mm. The refractive prediction errors of IOL power calculation formulas (SRK/T, Haigis, Holladay, Hoffer Q, and Barrett Universal II) using User Group f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cataract and refractive surgery
دوره 26 8 شماره
صفحات -
تاریخ انتشار 2000