Year-long validation study and reference values for urinary amino acids using a reversed-phase HPLC method.
نویسنده
چکیده
BACKGROUND Reversed-phase HPLC (RP-HPLC) has become an alternative to ion-exchange chromatography for amino acid analysis in biological fluids. However, validation studies for its urine application are limited, and the corresponding reference values have not been reported extensively. We studied the long-term performance of a commercial HPLC method for urine amino acid analysis and established specific age-related reference values for urine amino acid excretion. METHODS Method performance was continuously assessed by recovery and precision studies with urine samples and controls, respectively. Healthy individuals were prospectively analyzed throughout a 5-year period. Excretion of individual amino acids, expressed as mmol/mol of creatinine, was included in six age-related groups for random urine samples (0-1 month, 1-12 months, 1-3 years, 3-8 years, 8-16 years, and >16 years) and in two groups for 24-h urine collections (8-16 years and >16 years). RESULTS Over a 1-year period, CVs for retention times were <0.5% and 3.3% for within- and between-run imprecision, respectively. For amino acid concentrations, within-run CVs were 2.9-17% and between-run CVs were 7.1-46% for the same period. Amino acid recoveries were 78-122%. Reference intervals for 35 amino acids were calculated and compared with the concentrations observed in patients diagnosed with specific pathologies. A few statistically significant differences were found between the reference intervals derived using random and 24-h urine collections. CONCLUSIONS Long-term reliability of the RP-HPLC method for urine amino acid analysis has been demonstrated. Representative age-related reference intervals for the RP-HPLC method in both random urine and 24-h urine collections have been established, and their feasibility for diagnosis of aminoaciduria has been shown. These intervals could serve as a guide for laboratories changing to HPLC methods.
منابع مشابه
Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA
ABSTRACT Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...
متن کاملPerformance of 2-Amino Tetraphenyl Porphyrin as Stationary Phase in RP-HPLC of Amino Acids
The search for new stationary phases has been one of the predominant concerns in high performance liquid chromatography (HPLC) in order to achieve better resolutions, longer column lives, and reduce the time of analysis. A chromatographic packing for separation of underivatized amino acids (AAs) were prepared by dynamically coating 2-amino tetraphenyl prophyrin (atpp) on a C-18 reversed-pha...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملDevelopment and Validation of a Reversed-phase HPLC Method for Assay of the Decapeptide Cetrorelix Acetate in Bulk and Pharmaceutical Dosage Forms
A gradient reversed-phase high performance liquid chromatography (HPLC) method was developed for the assay of cetrorelix acetate, a synthetic decapeptide with gonadotropin-releasing hormone (GnRH) antagonistic activity used in infertility treatment. The HPLC method, which is used to determine cetrorelix in bulk and pharmaceutical dosage forms, was validated per ICH guidelines. The chromatograph...
متن کاملDiet-related reference values for plasma amino acids in newborns measured by reversed-phase HPLC.
We have measured by reversed-phase HPLC concentrations of amino acids in plasma in groups of 80 normal appropriate-weight term babies fed from birth either a casein formula (WhiteCap SMA, n = 26), a whey formula (Gold Cap SMA, n = 26), or breast milk (n = 28). They were studied from day 11 to week 15 postpartum. The trend was towards an increase in amino acid concentrations in plasma with age, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 47 3 شماره
صفحات -
تاریخ انتشار 2001