Reconstruction parameters for 111In-pentetreotide SPECT: variability with respect to body weight and body region.
نویسندگان
چکیده
UNLABELLED This study, which was based on a large series of consecutive patients imaged by (111)In-pentetreotide SPECT for a neuroendocrine tumor, evaluated variability in reconstruction parameters in relation to patient body weight and the body region imaged, looking for the possibility of standardizing such parameters. METHODS One hundred twenty-four patients underwent (111)In-pentetreotide scintigraphy: 4- and 24-h whole-body and planar scans and a 24-h SPECT examination. All patients were injected with 140-150 MBq of (111)In-pentetreotide at least 1 wk after somatostatin analogs had been discontinued. SPECT images were systematically acquired at the levels of the head, chest, and abdomen. SPECT was performed using a dual-head gamma-camera with medium-energy collimators, step-and-shoot method, no circular orbit, a 64 x 64 matrix, and 30 s per view for a total of 64 views. Two reconstruction procedures were compared: the iterative method using 10 iterations and the filtered backprojection method using a Butterworth filter with different cutoffs and orders. RESULTS Optimal SPECT images were obtained by applying the Butterworth filter. The reconstruction parameters could be standardized for the head and chest but were more variable for the abdomen, mainly because (111)In-pentetreotide is physiologically trapped in different intestinal areas and varies over time, especially in the liver, spleen, bowel, and urinary tract. CONCLUSION Filtered backprojection using a Butterworth filter appears adequate for standardizing the reconstruction parameters for (111)In-pentetreotide SPECT of the head and chest. Processing of abdominal images is more operator-dependent. A 150-MBq dose of (111)In-pentetreotide is recommended when planning multiple SPECT acquisitions in the same patient.
منابع مشابه
111In-pentetreotide scintigraphy and 18F FDG PET-CT in differentiated thyroid carcinoma metastases with negative whole body radioiodine scan.
Metastases of differentiated thyroid cancer (DTC) can lose affinity to radioiodine with the passage of time, with resultant difficulty in management. Thyroid tumors are known to express somatostatin receptors and therefore 111In-pentetreotide, somatostatin analogue, can visualize tumors with high concentration of somatostatin receptors. We report a case of I-131 whole body scan (WBS) negative r...
متن کاملImaging of somatostatin receptors by indium-111-pentetreotide correlates with quantitative determination of somatostatin receptor type 2 gene expression in neuroblastoma tumors.
We reported previously that the relative level of gene expression for sst2, a subtype of somatostatin receptors, was positively related to patient outcome in the childhood tumor neuroblastoma (NB). Because sst2 binds with high-affinity octreotide and its scintigraphic derivative, 111In-pentetreotide, we tested the hypothesis of whether NB tumor imaging with 111In-pentetreotide gives similar inf...
متن کاملDevelopment of 111In-labeled porphyrins for SPECT imaging
Objectives: The aim of this research was the development of 111In-labeled porphyrins as possible radiopharmaceuticals for the imaging of tumors. Methods: Ligands, 5, 10, 15, 20-tetrakis (3, 5-dihydroxyphenyl) porphyrin) (TDHPP), 5, 10, 15, 20-tetrakis (4-hydroxyphenyl) porphyrin (THPP) and 5, 10, 15, 20-tetrakis (3,4-dimethoxyphenyl) porphyrin) (TDMPP) were labeled with 111InCl3 (produced from ...
متن کاملRepeatability of Radiotracer Uptake in Normal Abdominal Organs with ¹¹¹In-Pentetreotide Quantitative SPECT/CT.
UNLABELLED With an increasing emphasis on quantitation of SPECT imaging and its use in dosimetry to guide therapies, it is desirable to understand the repeatability in normal-organ SPECT uptake values (SPECT-UVs). We investigated the variability of normal abdominal organ uptake in repeated (111)In-pentetreotide SPECT studies. METHODS Nine patients with multiple (111)In-pentetreotide SPECT/CT ...
متن کاملPredicting the Hamstring Tendon Diameter Using Anthropometric Parameters
Background: Despite the importance of hamstring tendon autograft, one major disadvantage in applying this technique in the surgical reconstruction of anterior cruciate ligament is individual variability in the tendon diameter. Hence, the purpose of the present study was to use anthropometric parameters such as gender, height and body mass index to predict 4-strand (quadruple) hamstring ten...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine technology
دوره 35 4 شماره
صفحات -
تاریخ انتشار 2007