Safety and feasibility of a novel adjustable mitral annuloplasty ring: a multicentre European experience†

نویسندگان

  • Martin Andreas
  • Nicolas Doll
  • Steve Livesey
  • Manuel Castella
  • Alfred Kocher
  • Filip Casselman
  • Vladimir Voth
  • Christina Bannister
  • Juan F. Encalada Palacios
  • Daniel Pereda
  • Guenther Laufer
  • Markus Czesla
چکیده

OBJECTIVES Recurrent mitral regurgitation is a significant problem after mitral valve repair in patients with functional valve disease. We report the safety and feasibility of a novel adjustable mitral annuloplasty device that permits downsizing of the anterior-posterior diameter late after initial surgery. METHODS In this multicentre, non-randomized, observational register, patients with moderate or severe mitral regurgitation undergoing surgical mitral valve repair with the MiCardia EnCorSQ™ Mitral Valve Repair system were evaluated. Patient characteristics, operative specifications and results as well as postoperative follow-up were collected for all five centres. RESULTS Ninety-four patients with a median age of 71 (64-75) years (EuroSCORE II 6.7 ± 6.3; 66% male, 48% ischaemic MR, 37% dilated cardiomyopathy and 15% degenerative disease) were included. Operative mortality was 1% and the 1-year survival was 93%. Ring adjustment was attempted in 12 patients at a mean interval of 9 ± 6 months after surgery. In three of these attempts, a technical failure occurred. In 1 patient, mitral regurgitation was reduced two grades, in 2 patients mitral regurgitation was reduced one grade and in 6 patients, mitral regurgitation did not change significantly. The mean grade of mitral regurgitation changed from 2.9 ± 0.9 to 2.1 ± 0.7 (P = 0.02). Five patients were reoperated after 11 ± 9 months (Ring dehiscence: 2; failed adjustment: 3). CONCLUSION We conclude that this device may provide an additional treatment option in patients with functional mitral regurgitation, who are at risk for reoperation due to recurrent mitral regurgitation. Clinical results in this complex disease were ambiguous and patient selection seems to be a crucial step for this device. Further trials are required to estimate the clinical value of this therapeutic concept.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First-in-man implantation of a trans-catheter aortic valve in a mitral annuloplasty ring: novel treatment modality for failed mitral valve repair.

The trans-catheter valve-in-valve concept has become a feasible therapeutic option for patients with failing degenerated bioprosthesis, who are deemed inoperable. However, little is known about the feasibility of this technique in failed valve annuloplasty. We report the first-in-man implantation of a trans-catheter aortic valve within a mitral annuloplasty ring. Through a trans-apical trans-ca...

متن کامل

Direct access transcatheter mitral annuloplasty with a sutureless and adjustable device: preclinical experience.

OBJECTIVES The aim of the study was to evaluate the technical feasibility and performance of a transcatheter mitral annuloplasty system. METHODS Adult swines (n = 15) underwent left thoracotomy through the 4th-5th intercostal space. A transcatheter device (CardioBand, Valtech-Cardio Ltd) was introduced through an 18F sheath through the left atrium and attached to the annulus between the poste...

متن کامل

Ringless MitraClip therapy: is it time to learn to give up?

I have read with interest the article by Taramasso et al. [1]. They compared retrospectively the efficacy of the MitraClip (percutaneous edge-to-edge [E2E] procedure) with surgical treatment (E2E stitch plus annuloplasty) in patients with severe functional mitral regurgitation (FMR) and heart failure. They concluded that MitraClip therapy is a good alternative, particularly in patients who are ...

متن کامل

Percutaneous transvenous Melody valve-in-ring procedure for mitral valve replacement.

OBJECTIVES The purpose of this study was to demonstrate the feasibility of percutaneous transvenous mitral valve-in-ring (VIR) implantation using the Melody valve in an ovine model. BACKGROUND The recurrence of mitral regurgitation following surgical mitral valve (MV) repair in both adult and pediatric patients remains a significant clinical problem. Mitral annuloplasty rings are commonly use...

متن کامل

Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus.

BACKGROUND Mitral annuloplasty is the most common surgical procedure performed for ischemic mitral regurgitation (MR). Surgical mitral annuloplasty is limited by morbidity, mortality, and MR recurrence. We evaluated the safety and feasibility of a transvenous catheter-delivered implantable device to provide a percutaneous alternative to surgical mitral annuloplasty. METHODS AND RESULTS Five p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2016