A Novel Non-contrast MR Angiography Technique using Triggered Non-Selective Refocused SPACE for Improved Spatial Resolution and Speed

نویسندگان

  • J. Xu
  • P. Weale
  • L. Gerhard
  • P. Schmitt
  • J. Park
  • B. Stoeckel
  • Q. Chen
  • R. P. Lim
  • A. Hardie
  • P. Storey
  • E. Hecht
  • K. Mcgorty
  • V. S. Lee
چکیده

Introduction: A non-contrast-enhanced MRA technique using gated 3D Turbo Spin Echo (TSE) has been reported for various clinical applications [1] [2], whereby systolic images are subtracted from diastolic images to provide high resolution MRA without exogenous contrast agents. Half-Fourier single-shot TSE results in a relatively long readout duration which causes vessel blurring due to T2 filtration effects and susceptibility to motion artifacts and arrhythmias. To reduce the long acquisition window for this cardiac imaging, one can use parallel imaging to reduce the acquired lines [3] and higher receiver bandwidth to reduce echo spacing time (ETS) [4],another potential solution to this limitation include multi-shot approach with the trade-off of increased scan time is less clinically acceptable especially as the technique is subtraction based and long scan times result in higher potential for motion between the corresponding systolic and diastolic scans. As an approach to alleviating the spatial resolution limitations and to improve the reliability of this technique in fast heart rates we have investigated the use of a variable flip angle method for non contrast MRA using triggered 3D SPACE (Sampling Perfection with Application optimized Contrasts by using different flip angle Evolutions), which uses selective RF excitation, non selective RF refocusing pulses and variable flip angles for contrast manipulation [5]. To determine times of peak and minimal flow within the cardiac cycle, triggered (pulse or ECG) phase contrast flow measurements were performed. SPACE helps achieve lower SAR and shorter ETS of 2 ms, resulting in total acquisition windows of around 100ms, a slice turbo factor in 3D direction can be used to speed up the acquisition, because two or more partitions can be acquired in one cardiac cycle. Figure 1 shows the intrinsic contrasts mechanisms between the two techniques, TSE based approach uses C-A, SPACE based approach use B-A. We performed a comparison between the SPACE and the TSE based approaches in terms of spatial resolution and reduced blurring and small vessel conspicuity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NATIVE SPACE Angiography with MTC and Fat Saturation Pulses

Introduction Non-contrast angiography emerges as an alternative method from contrast MRA due to the association of gadolinium based-agent with nephrogenic systemic fibrosis (NFS). A non-contrast MRA technique using gated 3D Turbo Spin Echo has been reported for various clinical applications [1][2]. Recently, a novel technique using triggered non-selective refocused 3D SPACE or called NATIVE SPA...

متن کامل

Free-breathing renal MR angiography with steady-state free-precession (SSFP) and slab-selective spin inversion: initial results.

BACKGROUND The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS Eight healthy volunteers (mean age 29 years) and eight patients...

متن کامل

Non-Contrast-Enhanced 4D MRA Using Compressed Sensing Reconstruction

Introduction : In the recent years, non-contrast magnetic resonance angiography (NCE MRA) has been an emerging tool in the diagnosis of degenerative vascular disease [1]. In this context, a novel time-resolved data acquisition method was proposed [2]. This technique uses two ECG-triggered CINE-like bSSFP acquisitions of multiple 3D phases: One after selective and another one after non-selective...

متن کامل

Non-contrast MR Angiography of the Toes: Correlations with Age and Gender

Purpose The aim of our study is to selectively visualize toe arteries without contrast media and exhibit correlations with age and gender. Non-contrast ECG-gated 3D half-Fourier FSE MR angiography with time-spatial labeling inversion pulses (time-SLIP) was investigated for efficacy in depicting the toe arteries using swap phase encode extended data (SPEED) acquisition. Materials and Methods All...

متن کامل

Non-contrast-enhanced 4D Intracranial MR Angiography with 4D NATIVE TrueFISP

Introduction: Conventional non-contrast-enhanced (NCE) MRA approaches including time-of-flight and phase contrast methods yield single frame static images or are limited in spatial resolution (typically by reverting to 2D rather than 3D methods) if multiphases ECG triggered acquisitions are used in the case of phase contrast. By administering T1-shortening contrast agents, timeresolved three-di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007