Analysis of liquid-phase chemical detection using guided shear horizontal-surface acoustic wave sensors.

نویسندگان

  • Zhonghui Li
  • Yolanda Jones
  • Jeanne Hossenlopp
  • Richard Cernosek
  • Fabien Josse
چکیده

Direct chemical sensing in liquid environments using polymer-guided shear horizontal surface acoustic wave sensor platforms on 36 degrees rotated Y-cut LiTaO3 is investigated. Design considerations for optimizing these devices for liquid-phase detection are systematically explored. Two different sensor geometries are experimentally and theoretically analyzed. Dual delay line devices are used with a reference line coated with poly (methyl methacrylate) (PMMA) and a sensing line coated with a chemically sensitive polymer, which acts as both a guiding layer and a sensing layer or with a PMMA waveguide and a chemically sensitive polymer. Results show the three-layer model provides higher sensitivity than the four-layer model. Contributions from mass loading and coating viscoelasticity changes to the sensor response are evaluated, taking into account the added mass, swelling, and plasticization. Chemically sensitive polymers are investigated in the detection of low concentrations (1-60 ppm) of toluene, ethylbenzene, and xylenes in water. A low-ppb level detection limit is estimated from the present experimental measurements. Sensor properties are investigated by varying the sensor geometries, coating thickness combinations, coating properties, and curing temperature for operation in liquid environments. Partition coefficients for polymer-aqueous analyte pairs are used to explain the observed trend in sensitivity for the polymers PMMA, poly(isobutylene), poly(epichlorohydrin), and poly(ethyl acrylate) used in this work.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Guided shear horizontal surface acoustic wave sensors for chemical and biochemical detection in liquids.

The design and performance of guided shear horizontal surface acoustic wave (guided SH-SAW) devices on LiTaO3 substrates are investigated for high-sensitivity chemical and biochemical sensors in liquids. Despite their structural similarity to Rayleigh SAW, SH-SAWs often propagate slightly deeper within the substrate, hence preventing the implementation of high-sensitivity detectors. The device ...

متن کامل

Theoretical mass, liquid, and polymer sensitivity of acoustic wave sensors with viscoelastic guiding layers

The theoretical sensitivity of Love wave and layer-guided shear horizontal acoustic plate mode ~SH-APM! sensors for viscoelastic guiding layers and general loading by viscoelastic materials is developed. A dispersion equation previously derived for a system of three rigidly coupled elastic mass layers is modified so that the second and third layers can be viscoelastic. The inclusion of viscoela...

متن کامل

Surface Generated Acoustic Wave Biosensors for the Detection of Pathogens: A Review

This review presents a deep insight into the Surface Generated Acoustic Wave (SGAW) technology for biosensing applications, based on more than 40 years of technological and scientific developments. In the last 20 years, SGAWs have been attracting the attention of the biochemical scientific community, due to the fact that some of these devices - Shear Horizontal Surface Acoustic Wave (SH-SAW), S...

متن کامل

Theory of QCM and SAW Devices in Sensors and Biosensors Applications

The surface acoustic waves-based (SAW) sensors and the quartz crystal microbalance (QCM) are widely employed for the ultrasensitive surface mass detection in volatile organic compounds and air quality control measurements. In ‘wet’’ conditions, the linear relation (Sauerbrey) between the rigidly attached small amount of deposited mass (the principle of a quartz microbalance) can be violated in ...

متن کامل

Digital phase detection approach and its application for AlN dual-mode differential surface acoustic wave sensing

Performance of a conventional phase detector implemented using analog circuitry is affected by, among other factors, the parameter value drifting of the analog components with environment (e.g., temperature) and time (i.e., aging). It is also adversely impacted by electromagnetic interferences likely existing in the analog circuits when the detector operates in a high frequency range. More impo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 77 14  شماره 

صفحات  -

تاریخ انتشار 2005