Wear of Crosslinked Uhmwpe in a Hip Joint Simulator

ثبت نشده
چکیده

Crosslinking has been extensively introduced to reduce the wear of UHMWPE. In this study the wear rates and wear surfaces of UHMWPE with different levels of crosslinking were compared in a hip joint simulator. The UHMWPE was either non-irradiated, gamma irradiated in air (2.5MRad), or highly crosslinked (7.5 and 10MRad). The intentionally crosslinked materials showed a significantly lower volume change compared to the non-crosslinked UHMWPE. The results of the surface topography of the acetabular cups showed that the highly crosslinked materials became smoother than the other materials as the test progressed. This would benefit the crosslinked materials in aiding lubrication. Finite wear rates have been recorded for the first time in simulator studies with highly crosslinked polyethylene. The wear rates and wear surfaces compare with those found in clinical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hip Microscopy Morphology MORPHOLOGY OF WEAR PARTICLES OF HEAVILY CROSS LINKED POLYETHYLENE

Introduction The orthopaedic industry has expended significant research effort in recent years in reducing wear of UHMWPE articulating surface components. One such approach has been in the development of a heavily crosslinked polyethylene. Crosslinking for long has been known to improve the wear resistance of industrial polyethylene. Clinical experience for over 20 years and an increasing magni...

متن کامل

Reduction of Wear in Fixed Bearing Total Knee Replacement Using Crosslinked Uhmwpe

Introduction Reduction of ultra high molecular weight polyethylene (UHMWPE) surface wear in total knee replacement (TKR) bearings may delay the onset of osteolysis and subsequent loosening of components. Crosslinking has been shown to increase the wear resistance of UHMWPE bearings in multidirectional total hip replacement applications when articulating against smooth counterfaces [1]. The aim ...

متن کامل

The Morphology of Uhmwpe Wear Debris Generated by a Hip Joint Simulator

THE MORPHOLOGY OF UHMWPE WEAR DEBRIS GENERATED BY A HIP JOINT SIMULATOR

متن کامل

Polyethylene Wear Debris From a Knee Simulator Model: Effect of Crosslinking and Counterface Material

INTRODUCION: Improved wear resistance of crosslinked UHMWPE has been well demonstrated in both hip and knee [1-4]. A reduction of 70% can be shown in knee simulators from conventional crosslinked tibial inserts (CXPE) gamma-irradiated at 3.5Mrad to 7Mrad highly crosslinked inserts (HXPE). Hip simulator models indicated that debris size decreased with increased crosslinking [5]. In the knee it h...

متن کامل

Effect of motion inputs on the wear prediction of artificial hip joints

Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005