Rod-Driven OFF Pathway Responses in the Distal Retina: Dark-Adapted Flicker Electroretinogram in Mouse

نویسنده

  • Bo Lei
چکیده

PURPOSE The rodent retina does not exhibit a positive OFF-response in the electroretinogram (ERG), which makes it difficult to evaluate its OFF-pathway functions in vivo. We studied the rod-driven OFF pathway responses by using a dark-adapted 10-Hz flicker ERG procedure in mouse. MATERIALS AND METHODS Conventional ERGs and 10-Hz dark-adapted flicker ERGs were obtained in wild-type mice (C57BL/6), in mice with pure rod (cpfl1) or pure cone (rho(-/-)) function, and in nob1 mice which have a selective ON-pathway defect. To isolate the response from ON or OFF pathway, glutamate analogs 2-amino-4-phosphobutyric acid (APB, an ON pathway blocker) and cis-2, 3-piperidine-dicarboxylic acid (PDA, an OFF pathway blocker), were injected intravitreally. RESULTS The amplitude-intensity profile of the dark-adapted 10-Hz flicker ERG in the wild-type mice exhibits two peaks at middle and high light intensities. The two peaks represent rod- and cone-driven responses respectively. In APB-treated C57BL/6 mice and in nob1 mice, the dark-adapted ERG b-waves were absent. However, both rod- and cone-driven OFF pathway responses were evident with flicker ERG recording. At middle light intensities that activate only rod system, the flicker ERG responses in saline-injected nob1 mice were similar to those in APB-injected cpfl1 mice and wild-type mice. These responses are sensitive to PDA. The amplitudes of these rod-driven OFF pathway responses were approximately 20% of the total rod-driven flicker ERG responses. CONCLUSION We demonstrate that the rod-OFF bipolar cell pathway is functional in the outer retina. The dark-adapted flicker ERG is practical for the evaluation of rod- and cone-driven responses, and the residual OFF pathway signals in subjects with ON pathway defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mesopic background lights enhance dark-adapted cone ERG flash responses in the intact mouse retina: a possible role for gap junctional decoupling.

The cone-driven flash responses of mouse electroretinogram (ERG) increase as much as twofold over the course of several minutes during adaptation to a rod-compressing background light. The origins of this phenomenon were investigated in the present work by recording preflash-isolated (M-)cone flash responses ex vivo in darkness and during application of various steady background lights. In this...

متن کامل

Prenatal Hypoxia Is Associated with Long-Term Retinal Dysfunction in Rats

BACKGROUND Intra-uterine growth restriction (IUGR) has been associated with increased predisposition to age-related complications. We tested the hypothesis that rat offspring models of IUGR would exhibit exacerbated, age-related retinal dysfunction. METHODS Female Sprague-Dawley rats (maintained at 11.5% O2 from gestational day 15 to 21 to induce IUGR) and control offspring (maintained at 21%...

متن کامل

The electroretinogram in dogs with inherited cone degeneration.

The electroretinogram (ERG) of hemeralopic Alaskan malamute dogs contains only rod components. There is absence of the photopic b-wave which is normally elicited with red light stimuli during dark adaptation and, using flicker stimulation, only the first or rod branch of the flicker fusion response curve is present. At high stimulus intensity levels, the flicker response of hemeralopes is absen...

متن کامل

Genetic dissection of rod and cone pathways in the dark-adapted mouse retina.

A monumental task of the mammalian retina is to encode an enormous range (>10(9)-fold) of light intensities experienced by the animal in natural environments. Retinal neurons carry out this task by dividing labor into many parallel rod and cone synaptic pathways. Here we study the operational plan of various rod- and cone-mediated pathways by analyzing electroretinograms (ERGs), primarily b-wav...

متن کامل

Investigating the frequency characteristics of the electroretinogram signal in patients with central retinal vein occlusion

Background: Central retinal vein occlusion (CRVO) is the second most common retinal vascular disorder after diabetic retinopathy. In this study, we tried to examine the potentials of time-frequency methods for differentiating the eyes with CRVO. Materials and methods: Twenty patients with unilateral CRVO were included in this study. Their contralateral normal eyes were considered as the control...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012