Evaluation of an immunoassay for determination of plasma efavirenz concentrations in resource-limited settings
نویسندگان
چکیده
INTRODUCTION Therapeutic drug monitoring (TDM) may improve antiretroviral efficacy through adjustment of individual drug administration. This could result in reduced toxicity, prevent drug resistance, and aid management of drug-drug interactions. However, most measurement methods are too costly to be implemented in resource-limited settings. This study evaluated a commercially available immunoassay for measurement of plasma efavirenz. METHODS The immunoassay-based method was applied to measure efavirenz using a readily available Humastar 80 chemistry analyzer. We compared plasma efavirenz concentrations measured by the immunoassay with liquid chromatography tandem mass spectrometry (LC-MS/MS) (reference method) in 315 plasma samples collected from HIV patients on treatment. Concentrations were categorized as suboptimal<1 µg/ml, normal 1-4 µg/ml or high>4 µg/ml. Agreement between results of the methods was assessed via Bland-Altman plot and κ statistic values. RESULTS The median Interquartile range (IQR) efavirenz concentration was 2.8 (1.9; 4.5) µg/ml measured by the LC-MS/MS method and 2.5 (1.8; 3.9) µg/ml by the immunoassay and the results were well correlated (ρ=0.94). The limits of agreement assessed by Bland-Altman plots were -2.54; 1.70 µg/ml. Although immunoassay underestimated high concentrations, it had good agreement for classification into low, normal or high concentrations (K=0.74). CONCLUSIONS The immunoassay is a feasible alternative to determine efavirenz in areas with limited resources. The assay provides a reasonable approximation of efavirenz concentration in the majority of samples with a tendency to underestimate high concentrations. Agreement between tests evaluated in this study was clinically satisfactory for identification of low, normal and high efavirenz concentrations.
منابع مشابه
Development of a single-tube, low-cost, analytical process to extract, separate and determine efavirenz and rifampicin plasma concentrations in HIV/TB co-infected patients
Background Tuberculosis (TB) complicating HIV-1 infection is a persistent significant clinical concern, particularly in resource limited settings. Treatment of HIV-infected patients with TB often comprises efavirenz-containing antiretroviral regimens particularly when on TB treatment containing rifampicin. Although rifampicin may reduce EFV concentrations, little is known of the effect of the H...
متن کاملThe effects of interactions between testosterone and ghrelin on mean plasma thyroid hormones concentration in male rats
Ghrelin is an orexigenic peptide synthesized mainly by stomach and hypothalamus. Ghrelin decreases secretion of thyroid hormones. Testosterone is an esteroidogenic hormone that exerts stimulatory effects on Hypothalamus-Pituitary-Thyroid (HPT) axis activity. The aim of the present study was to investigate the effect of interactions between the central injection of ghrelin and testosterone on me...
متن کاملA Randomized Comparison of Anthropomorphic Changes With Preferred and Alternative Efavirenz-Based Antiretroviral Regimens in Diverse Multinational Settings
Background. Existing data on anthropomorphic changes in resource-limited settings primarily come from observational or cross-sectional studies. Data from randomized clinical trials are needed to inform treatment decisions in these areas of the world. Methods. The AIDS Clinical Trials Group Prospective Evaluation of Antiretrovirals in Resource-Limited Settings (PEARLS) study was a prospective,...
متن کاملThe Continued Utility and Viability of Dakin’s Solution in Both High- and Low-resource Settings
Healthcare is expensive and often inaccessible to many. As a result, surgeons must consider simple, less expensiveinterventions when possible. For wound care, an older but quite effective cleaning agent is Dakin’s solution (0.5%sodium hypochlorite), an easily made mixture of 100 milliliters (ml) bleach with 8 teaspoons (tsp) baking soda into agallon of clean water or 25 ml ble...
متن کاملBlood folate concentrations analyzed by microbiological assay and chemiluminescent immunoassay methods.
A limited number of studies have been available to compare blood folate concentrations by the microbiological assay (MA) method with those using the chemiluminescent immunoassay (CLIA) method. We compared folate concentrations measured by Lactobacillus rhamnosus MA with those measured by CLIA (Access Immunoassay Systems) in human plasma/serum and erythrocytes pairs (n=35). The mean plasma folat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2014