Spectral domain optical coherence tomography and B-scan ultrasonography in the evaluation of retinal tears in acute, incomplete posterior vitreous detachment

نویسندگان

  • Solmaz Abdolrahimzadeh
  • Domenica Carmen Piraino
  • Vittorio Scavella
  • Barmak Abdolrahimzadeh
  • Filippo Cruciani
  • Magda Gharbiya
  • Santi Maria Recupero
چکیده

BACKGROUND The purpose of this study was to evaluate the extension and traction effects of posterior vitreous detachment (PVD) complicated with retinal tears using spectral domain optical coherence tomography (OCT) and B-scan ultrasonography. METHODS Complete ophthalmological examination, B-scan ultrasonography and spectral domain OCT were performed in patients with acute PVD and retinal tears. Vitreous detachment was classified as complete or incomplete, based on extent of posterior pole or peripheral vitreous detachment. Retinal tear location and persistent traction on the retinal flap was evaluated with B-scan ultrasonography and OCT. Categorical data were evaluated with Fisher's exact test. Statistical significance was considered as P < 0.05. RESULTS Twenty-six eyes of 25 patients were assessed. Four eyes (15 %) presented complete PVD with detachment at the posterior pole and periphery. 22 eyes (85 %) presented incomplete PVD with detachment in the periphery. Twenty eyes presented retinal tears in the superior quadrants with respect to only 6 in the inferior quadrants (p = 0.006). There was a higher incidence of retinal tears in the pre with respect to post-equatorial areas (19 vs 7 eyes, p = 0.019). B-scan ultrasonography and OCT revealed persistent traction on the retinal tear flap in 19 and 15 eyes, respectively. CONCLUSIONS In acute PVD, retinal tears are prevalently associated with peripheral vitreous detachment. The impact of complete or incomplete PVD can be of clinical value when evaluating patients with retinal tears.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography findings of the vitreoretinal interface in asymptomatic fellow eyes of patients with acute posterior vitreous detachment.

PURPOSE To describe the vitreoretinal interface of the asymptomatic fellow eyes of patients with acute unilateral posterior vitreous detachment (PVD) based on biomicroscopic examination and spectral domain optical coherence tomography. METHODS Sixty-five eyes of 65 consecutive patients with acute unilateral PVD were examined by slit-lamp, indirect ophthalmoscopy, and spectral domain optical c...

متن کامل

Optical coherence tomography for diagnosis of posterior vitreous detachment at the macular region.

PURPOSE To assess optical coherence tomography (OCT) for diagnosing posterior vitreous detachment (PVD) at the macular region compared to kinetic B-scan ultrasonography. METHODS In the present study, the authors prospectively investigated the frequency of PVD at the posterior pole utilizing ocular kinetic B-mode sonography in 315 eyes of 188 patients (113 female, 75 male; mean age, 72.8 years...

متن کامل

Retinal Ganglion Cell Complex in Alzheimer Disease: Comparing Ganglion Cell Complex and Central Macular Thickness in Alzheimer Disease and Healthy Subjects Using Spectral Domain-Optical Coherence Tomography

Introduction: Alzheimer disease (AD) is the most common form of dementia worldwide. The modalities to diagnose AD are generally expensive and limited. Both the central nervous system (CNS) and the retina are derived from the cranial neural crest; therefore, changes in retinal layers may reflect changes in the CNS tissue. Optical coherence tomography (OCT) machine can show delicate retinal layer...

متن کامل

Pulse-encoded ultrasound imaging of the vitreous with an annular array.

The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved ...

متن کامل

Novel perspectives on swept-source optical coherence tomography

Technologies for multimodal digital imaging of vitreoretinal diseases have improved the accuracy of diagnosis and the depth of the knowledge of the mechanisms of disease and their response to treatments. Optic coherence tomography (OCT) has become a mandatory tool for the management and for the follow-up of retinal pathologies. OCT technology evolved in the last two decades from time-domain to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016