In situ evaluation of solute retardation using single-well push±pull tests
نویسندگان
چکیده
More ecient methods are needed for the in situ evaluation of solute sorption to aquifer sediments. The objective of this study was to develop a simpli®ed method for estimating retardation factors for injected solutes from ``push±pull'' test extraction phase breakthrough curves (BTCs). Sensitivity analyses based on numerical simulations were used to evaluate the method performance for a variety of test conditions. Simulations were conducted for varying retardation factors, aquifer parameters and injection phase durations, for tests performed under nonideal transport conditions such as nonlinear equilibrium and linear nonequilibrium sorption, and for a test performed in a physically heterogeneous aquifer. Predicted retardation factors showed errors 614% in tests performed under ideal transport conditions (physically homogeneous aquifer with spatially uniform dispersivity that does not vary from solute to solute, spatially uniform linear equilibrium sorption). The method performed more poorly for solutes with large retardation factors R > 20 and for tests conducted under nonideal transport conditions, and is expected to perform poorly in aquifers with highly heterogeneous sorption. In an example application, we used the method to estimate the distribution coecient for Sr using data from a ®eld test performed by Pickens JF, Jackson RE, Inch KJ, Merritt WF. (Water Resour Res 1981;17:529± 44). Reasonable agreement was found between distribution coecients obtained using the simpli®ed method of estimation and those obtained by Pickens et al. (1981). Ó 2000 Elsevier Science Ltd. All rights reserved.
منابع مشابه
A note on in situ estimates of sorption using push-pull tests
[1] A sensitivity analysis reveals that large uncertainty exists in estimates of solute retardation factor R made from sorption push-pull tests. A simplified push-pull data interpretation method for estimating instantaneous linear sorption in confined aquifers is developed. The new method is less restrictive in its application than the conventional method that uses an approximate analytical sol...
متن کامل"Forced mass balance" technique for estimating in situ transformation rates of sorbing solutes in groundwater.
A method for estimating in situ transformation rates of sorbing solutes in groundwater is presented. The method utilizes a novel data processing technique called "forced mass balance" (FMB) to remove the effects of transport processes from reactant and product concentrations measured during single-well, "push-pull" tests. The effectiveness of the FMB technique was evaluated by quantifying error...
متن کاملStatic and push-pull methods using radon-222 to characterize dense nonaqueous phase liquid saturations.
Naturally occurring radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and noncontaminated portions of an aquifer, while the push-pull method involves the injection (push) and extraction (pull) of a rad...
متن کاملEvaluation of the in-situ aerobic cometabolism of chlorinated ethenes by toluene-utilizing microorganisms using push-pull tests.
A series of transport, biostimulation, and activity push-pull tests were performed under induced and natural gradient conditions in a trichloroethene (TCE) and cis-dichloroethene (c-DCE) contaminated aquifer. Transport tests demonstrated the feasibility of injecting and recovering complex solute mixtures from the aquifer. During the biostimulation tests, decreases in toluene concentration and t...
متن کاملPush-pull partitioning tracer tests using radon-222 to quantify non-aqueous phase liquid contamination.
Naturally occurring radon in groundwater can be used as an in situ partitioning tracer for locating and quantifying non-aqueous phase liquid (NAPL) contamination in the subsurface. When combined with the single-well, push-pull test, this methodology has the potential to provide a low-cost alternative to inter-well partitioning tracer tests. During a push-pull test, a known volume of test soluti...
متن کامل