Understanding and caring for a Schiotz tonometer
نویسنده
چکیده
A Schiotz tonometer is an instrument for measuring the intraocular pressure (IOP). Although the Schiotz tonometer does not make as precise measurements as other types of tonometers, it is inexpensive, simple to use, durable, requires little maintenance, does not have electronics, does not require batteries, and can be stored for years between uses. These qualities make it well suited for screening and remote or mobile clinics. The Schiotz tonometer consists of a hollow barrel with a concave footplate and a holder (Figure 1). A free-fl oating, rod-like plunger with a 5.5 gram weight attached fi ts inside the barrel. When held vertically on top of the eye, the plunger will move downwards by gravity and indent the cornea. This very small up-and-down movement is magnifi ed by a lever arm to move a needle that gives a reading on a horizontal scale numbered arbitrarily 0–20. A fi rmer eye, due to higher IOP, will result in a lower indentation and a lower reading on the scale. Since the Schiotz tonometer does not measure pressure directly, a conversion table, supplied with the instrument, is used to translate scale readings into estimates of IOP in mmHg. To account for the range of pressure, other weights (typically 7.5 g and 10 g) are supplied that can be added to the plunger.
منابع مشابه
Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
PURPOSE Post-Descemet stripping endothelial keratoplasty (DSEK) patients are prone for intraocular pressure (IOP) elevations and glaucoma. Corneal characteristics influence various IOP measuring devices in various ways. The aim of this study was to evaluate the agreement between four different IOP measuring devices: Goldmann applanation tonometer (GAT), I-care pro, Tonopen XL, and Schiotz tonom...
متن کاملSchiötz tonometers. An assessment of their usefulness.
THERE is no doubt that applanation tonometry gives more accurate information about the level of intra-ocular pressure than does indentation tonometry. This increased accuracy is due to the fact that applanation readings approach very closely to the levels of pressure in the undisturbed eye (Po), owing to the small volume of fluid displaced by the application of the tonometer (Goldmann, 1957). A...
متن کاملEffect of Tonography on Facility of Outflow.
In enucleated stored eyes facility of outflow is diminished by large corneal distortions. The radius of distortion at which decrease in facility is noted is related to the shape of the distortion. Of the three distorting devices tested, a plane surface decreased the facility at the smallest radius of distortion, a convex surface was intermediate in effect, while the Schiotz tonometer allowed th...
متن کاملStandardized x-tonometers.
STANDARDIZED Schi6tz tonometers of the original (weighted) type have been on sale in the United States for more than 10 years, and a considerable amount of information has been collected which bears out the acceptability of the current specification. This knowledge was assembled in the First Decennial Report of the Committee on Standardization of Tonometers (1954). Following the American lead, ...
متن کاملTheory and calibration of the Schiotz tonometer. II. The resistance of the cornea to deformation.
.lthough the cornea is very flexible, force must be required to bend it. Goldmann and Schmidt' and Gloster and Perkins following Imbert and Fick have considered bending resistance in applantation tonometry. Friedenwald however, in his studies on Schi0tz tonometry, came to the conclusion that the resistance of the cornea to deformation is negligibly small. The corneal bending forces involved in ...