Comparison of the non-invasive Nexfin® monitor with conventional methods for the measurement of arterial blood pressure in moderate risk orthopaedic surgery patients

نویسندگان

  • Felix Balzer
  • Marit Habicher
  • Michael Sander
  • Julian Sterr
  • Stephanie Scholz
  • Aarne Feldheiser
  • Michael Müller
  • Carsten Perka
  • Sascha Treskatsch
چکیده

OBJECTIVE Continuous invasive arterial blood pressure (IBP) monitoring remains the gold standard for BP measurement, but traditional oscillometric non-invasive intermittent pressure (NIBP) measurement is used in most low-to-moderate risk procedures. This study compared non-invasive continuous arterial BP measurement using a Nexfin® monitor with NIBP and IBP monitors. METHODS This was a single-centre, prospective, pilot study in patients scheduled for elective orthopaedic surgery. Systolic BP, diastolic BP and mean arterial blood pressure (MAP) were measured by Nexfin®, IBP and NIBP at five intraoperative time-points. Pearson correlation coefficients, Bland-Altman plots and trending ability of Nexfin® measurements were used as criteria for success in the investigation of measurement reliability. RESULTS A total of 20 patients were enrolled in the study. For MAP, there was a sufficient correlation between IBP/Nexfin® (Pearson = 0.75), which was better than the correlation between IBP/NIBP (Pearson = 0.70). Bland-Altman analysis of the data showed that compared with IBP, there was a higher percentage error for MAPNIBP (30%) compared with MAPNexfin® (27%). Nexfin® and NIBP underestimated systolic BP; NIBP also underestimated diastolic BP and MAP. Trending ability for MAPNexfin® and MAPNIBP were comparable to IBP. CONCLUSION Non-invasive BP measurement with Nexfin® was comparable with IBP and tended to be more precise than NIBP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of direct and indirect blood pressure in patients under esophagectomy surgery: a prospective observational study

Background: Arterial pressure is one of the most important physiological variables and often needs to be monitored repeatedly or continuously in perioperative period. Arterial pressure monitoring is one of the standard monitoring in operating room. During general anesthesia, blood pressure can be measured by using a noninvasive arterial pressure method or continuous invasive arterial pressure b...

متن کامل

Level of agreement between Nexfin non-invasive arterial pressure with invasive arterial pressure measurements in children.

BACKGROUND We compared Nexfin non-invasive arterial pressure measurements using a novel small finger cuff with intra-arterial pressure in the paediatric setting in order to establish the level of agreement between both methods. METHODS The study included 41 children aged 2-16 yr admitted for surgery or paediatric intensive care with an intra-arterial catheter as part of standard monitoring. V...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

Comparison of hemodynamic changes in patients using conventional laryngoscopy and video laryngoscope in surgery

Introduction: One of the complications of laryngoscopy and endotracheal intubation is sympathetic stimulation with hemodynamic changes that are always tried to be avoided by anesthesiologists. The aim of this study is to review and compare hemodynamic changes caused by both conventional and video laryngoscopy. Methods: In this clinical trial performed in 2015 in the Birjand-based Imam Reza Hosp...

متن کامل

Non-invasive continuous arterial pressure and cardiac index monitoring with Nexfin after cardiac surgery.

BACKGROUND This observational study was designed to evaluate the reliability and precision of a new digital photoplethysmographic device (Nexfin, BMEYE B.V., Amsterdam, The Netherlands) for continuous and non-invasive assessment of arterial pressure and cardiac output. METHODS Fifty consecutive adult subjects were prospectively enrolled at admission to the intensive care unit after convention...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 44  شماره 

صفحات  -

تاریخ انتشار 2016