Composite electrodes with carbon supported Ru nanoparticles for H2O2 detection.

نویسندگان

  • Valdrin Januzaj
  • Vllaznim Mula
  • Graziella L Turdean
  • Liana Maria Muresan
چکیده

A new carbon paste electrode (CPE) incorporating Ru - nanoparticles (RuNP) stabilized on graphite powder was developed for H(2)O(2) amperometric detection. Cyclic voltammetric measurements, performed in phosphate buffer solutions at different potential scan rates and different potential ranges were carried out in order to evaluate the electrochemical behavior of the CPE-RuNP modified electrodes. From amperometric measurements performed at -0.1 V vs. Ag/AgCl, KClsat, the electrocatalytic efficiency toward H(2)O(2) reduction was evaluated and it was found in the range: 28.47% (CPE) < 94.81% (CPE-RuNP (2.5:1)) < 118.19 % (CPE-RuNP (2.5:3)) < 152.43% (CPE-RuNP (2.5:2), recommending the new electrodes as promising sensors for hydrogen peroxide detection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrodeposition of anionic, cationic and nonionic surfactants and gold nanoparticles onto glassy carbon electrode for catechol detection

Three surfactants were selected to modify glassy carbon electrode including sodiumdodecylbenzenesulfonate, Tween 80 and cetyltrimethylammonium bromide. The obtained nano-Au/surfactant/GCEs were characterized with scanning electron microscopy and electrochemicaltechniques. Electrochemical behavior of catechol at the nano-Au/surfactant/GCE was thoroughlyinvestigated for mo...

متن کامل

Pd nanoparticle-modified electrodes for nonenzymatic hydrogen peroxide detection

A hydrogen peroxide (H2O2) sensor based on Pd nanoparticles (NPs) and glassy carbon electrodes (GCEs) is fabricated. Pd NPs are deposited on GCEs by using a gas phase cluster beam deposition technique. The NP-deposited electrodes show enhanced electrocatalytic activity in reduction of H2O2. The electrode with an optimized NP coverage of 85 % has a high selective and stable nonenzymatic sensing ...

متن کامل

Detection of Clindamycin in Pharmaceutical Products using an Electrochemiluminescence Electrode based on a Composite of Ru(bpy)3²+, Eu2O3 Nanoparticle and Chitosan

In this study, the electrochemiluminescence (ECL) interaction of clindamycin and tris(2,2′-bipyridine)ruthenium(II) (Ru(bpy)32+) was used to develop a sensitive tool for the detection of clindamycin based on modifying a glassy carbon electrode (GCE) with nanoparticles of europium oxide. The experiments showed that in the presence of these inorganic nanoparticles (Eu2<...

متن کامل

Determination of Acetaminophen Via TiO2/MWCNT Modified Electrode

Electrochemical behaviour of acetaminophen at the multi wall carbon nanotubes/titanium dioxide (MWCNT/TiO2) composite film modified glassy carbon electrode (GCE) via solvent casting method was studied. It is shown that the MWCNT/TiO2/GCE exhibits remarkable improvement in analytical response as compared to other electrodes. Comparing the responses of the MWCNT/TiO2/GCE with that obtained at the...

متن کامل

Graphene Oxide/Polyaniline-Based Multi Nano Sensor for Simultaneous Detection of Carbon Dioxide, Methane, Ethanol and Ammonia Gases

In this study, a multi nanosensor was fabricated for the simultaneous detection of carbon dioxide, methane, ethanol, and ammonia gases, and its electrochemical response to various concentrations of these gases were investigated. In order to fabricate this multi nanosensor, in the first phase, the Graphene-Oxide/Polyaniline (GO/PANI) nanocomposite was synthesized. Chemical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta chimica Slovenica

دوره 62 1  شماره 

صفحات  -

تاریخ انتشار 2015