Minimally invasive hollow trephine technique is recommended for revision of broken uncemented and extensively porous-coated monolithic femoral stems: a review of three cases.
نویسندگان
چکیده
Revisions of fractured, uncemented and extensively porous-coated femoral stems are challenging. In this article, we report three cases of revision surgeries for broken, cementless, and extensively porous-coated femoral stems with Solution stems (DePuy, Warsaw, Indiana). In all cases, minimally invasive endofemoral revision was successfully performed without femoral osteotomy or cortical fenestration. Removal of distal broken femoral stem was performed with hollow trephine technique under fluoroscopy. For revision arthroplasty of the femoral component, Solution stems of larger diameter were used. Endofemoral approach reduces duration of surgery and the amount of blood and bone loss. Minimally invasive technique for broken and uncemented femoral stem is recommended.
منابع مشابه
The use of uncemented extensively porous-coated femoral components in the management of Vancouver B2 and B3 periprosthetic femoral fractures.
We assessed the outcome of patients with Vancouver type B2 and B3 periprosthetic fractures treated with femoral revision using an uncemented extensively porous-coated implant. A retrospective clinical and radiographic assessment of 22 patients with a mean follow-up of 33.7 months was performed. The mean time from the index procedure to fracture was 10.8 years. There were 17 patients with a sati...
متن کاملExtensively porous-coated stems for femoral revision: reliable choice for stem revision in Paprosky femoral type III defects.
Between January 1999 and August 2008, ninety-six femoral revisions were performed with extensively porous-coated stems in Paprosky type III femoral defects (89 type IIIA and 7 type IIIB defects). Seven type IIIB defects with a mean canal of 16.5 mm were observed; 6 defects achieved stable bone ingrowth and 1 achieved stable fibrous condition. Average postoperative Harris Hip Score was 92.3±8 (r...
متن کاملEpidemiology of periprosthetic femoral fractures in 5417 revision total hip arthroplasties: a 40-year experience.
AIMS The goals of this study were to define the risk factors, characteristics, and chronology of fractures in 5417 revision total hip arthroplasties (THAs). PATIENTS AND METHODS From our hospital's prospectively collected database we identified all patients who had undergone a revision THA between 1969 and 2011 which involved the femoral stem. The patients' medical records and radiographs wer...
متن کاملA collarless cobalt-chrome femoral component in uncemented total hip arthroplasty. Five- to eight-year follow-up.
We implanted 57 uncemented cobalt-chrome porous-coated collarless femoral components into 51 patients (mean age 49 years). At review, five to eight years postoperatively, good or excellent results were recorded in 70% by the Mayo Clinic hip evaluation and in 84% by the Harris hip score. Revision for aseptic loosening of the femoral stem was necessary in only one hip. Thigh pain diminished with ...
متن کاملRevision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem
BACKGROUND To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty. METHODS This study reviewed the results of 35 patients who received a revision total hip arthroplasty with extensively porous coated femoral stem between August, 1996, and December, 2002. The mean follow-up period was 77.5 months. The clinical and radiologica...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery
دوره 25 2 شماره
صفحات -
تاریخ انتشار 2014