A Novel Technique of Measuring Distance Stereo-Acuity Using TNO Chart and Inverted Telescope

ثبت نشده
چکیده

In a strabismus clinic, measurement of distance stereopsis is particularly useful in the management of intermittent exotropia and esotropia of divergence paralysis type. This is mainly because reduction in the distance stereopsis is a sensitive sign of early deterioration of these strabismic disorders and generally makes a case for the surgical intervention [10]. Various tests have been used for the measurement of stereoacuity for the near [11]. Titmus/Wirt Fly test, Randot test and TNO test are among the more popular ones. For the distance stereopsis, the Mentor BVAT SG [12] and Frisby Davis distance stereo test (FD2) [13] are fairly accurate and versatile. However, the distance stereoacuity tests are not commonly available in the clinics and they are relatively expensive. In the present study, we have explored the option of using the TNO test that uses red-green random dot stereopairs (anaglyphics) with an inverted telescope to measure the global, crossed disparity induced, central stereopsis. To our knowledge this is the first paper in the literature to optically induce the distance using a telescope in an inverted fashion and combine its use with a near stereoacuity assessment chart for the measurement of distance stereoacuity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of a Novel Stereoacuity Test Device Using a High-Resolution 3D Monitor

Purpose: To develop stereoacuity test using a high-resolution 3D monitor and examined the effects of the monitor on the measured stereoacuity. Methods: We conducted stereoacuity test using a high-resolution 3D monitor. This 3D monitor can show parallax of 27 s (crossed) at the minimum at measurement distance 40 cm, and circularly polarized glasses were used for binocular separation. Titmus ster...

متن کامل

Successful Closure of Iatrogenic Double Macular Hole Using inverted Internal Limiting Membrane Flap Technique-Case Report

Purpose: To present a case study describing inverted internal limiting membrane flap technique used after failed treatment of double large fullthickness macular hole. Case presentation: A 79-year-old woman presented large full-thickness macular hole after primary failed pars plana vitrectomy with internal limiting membrane (ILM) peeling and SF6 gas endotamponade. The corrected distance visual a...

متن کامل

Measuring the Influence of Galilean Loupe System on Near Visual Acuity of Dentists under Simulated Clinical Conditions.

AIM The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC) with near visual acuity of those using the Galilean telescope system (VGA2) with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. METHODS The study included 46 dentists (visual acuity 1.0 without correction). A visual acuity testing was carried out using a...

متن کامل

A Novel Method for Impedance Calculation of Distance Relays Using Third Order Interpolation

All algorithms for impedance calculation use an analog-to-digital converter. The high accuracy of the impedance seen by a distance relay is an important factor in the correct isolation of the faulty part of power systems. To achieve this, a novel technique based on third order interpolation is used in this paper. According to this technique, the times and the values of the obtained samples are...

متن کامل

A Novel Method for Impedance Calculation of Distance Relays Using Third Order Interpolation

All algorithms for impedance calculation use an analog-to-digital converter. The high accuracy of the impedance seen by a distance relay is an important factor in the correct isolation of the faulty part of power systems. To achieve this, a novel&#10technique based on third order interpolation is used in this paper. According to this technique, the times and the values of the obtained samples a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017