Investigation of selective retina treatment (SRT) by means of 8 ns laser pulses in a rabbit model.

نویسندگان

  • Carsten Framme
  • Georg Schuele
  • Karin Kobuch
  • Barbara Flucke
  • Reginald Birngruber
  • Ralf Brinkmann
چکیده

BACKGROUND It has been shown that selective retina treatment (SRT) using a train of 1.7 microseconds laser pulses allows selective damage of the retinal pigment epithelium (RPE) while sparing the adjacent photoreceptors and thus avoiding laser scotoma. It was the purpose of this work to investigate SRT laser effects with Q-switched pulses of only 8 nanoseconds in duration by evaluating the angiographic and ophthalmoscopic damage thresholds and the damage range by histology in a rabbit model. MATERIALS AND METHODS A flash lamp pumped frequency doubled (532 nm) Nd:YAG laser with 8 nanoseconds pulse duration was used. In total 210 laser lesions, each calculated to be 102 microm in diameter on retina, were applied through a slit lamp onto the fundus of six eyes of Chinchilla Bastard rabbits. The rabbits were irradiated with increasing energies with single pulses and a train of 10 laser pulses at 10 Hz. After treatment fundus photography and angiography were performed to determine the damage thresholds (ED(50)-probability of RPE cell damage and neurosensory retinal damage) as well as the safety range between both thresholds (ratio of angiographic ED(86) vs. ophthalmoscopic ED(14)). Selected histology was taken for single and repetitive pulse lesions after treatment. RESULTS Angiographic and ophthalmoscopic ED(50)-thresholds decreased with increasing number of pulses. For single pulse application ophthalmoscopic and angiographic ED(50) were determined to 365 and 144 mJ/cm(2), respectively. Regarding 10 pulses 266 and 72 mJ/cm(2) were found. No retinal hemorrhages or disruptions were observed for both sets of parameters. The therapeutic window between angiographic and ophthalmoscopic threshold revealed a factor of 3.1 for single pulses and 2.3 for repetitive pulse irradiation. The safety range respectively had a factor of 0.8 (single pulses) and 1.7 (10 pulses). Histologic examination of laser lesions with single and repetitive pulses at radiant exposures within the therapeutic window-292 and 213 mJ/cm(2) respectively-revealed damaged RPE, intact Bruch's membrane and choriocapillaries. Photoreceptors were partly spared but also damaged to various extents. CONCLUSIONS Short laser pulses of 8 nanoseconds pulse duration can damage the RPE without retinal hemorrhage or disruption. Selective damage of the RPE without affecting the photoreceptors can only rarely be achieved due to the small safety range. Thus, so far microsecond laser pulses for SRT seems favorable compared to nanosecond pulses in order to prevent unintentional photoreceptor damage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Structural changes of the retina after conventional laser photocoagulation and selective retina treatment (SRT) in spectral domain OCT.

BACKGROUND Spectral domain optical coherence tomography (SD-OCT) in patients can deliver retinal cross-sectional images with high resolution. This may allow the evaluation of the extent of damage to the retinal pigment epithelium (RPE) and the neurosensory retina after laser treatment. This article aims to investigate the value of SD-OCT in comparing laser lesions produced by conventional laser...

متن کامل

A Comparative Study of Retinal Function in Rabbits after Panretinal Selective Retina Therapy versus Conventional Panretinal Photocoagulation

Purpose. This study evaluates functional changes in electroretinographic findings after selective retina therapy (SRT) compared to panretinal photocoagulation (PRP) in rabbits. Methods. The right eyes of 12 Chinchilla rabbits received 200 laser treatment spots. The right eyes of six rabbits received SRT (SRT group), whereas the other six animals were treated using PRP on the right eye (PRP grou...

متن کامل

Effects of Laser Physical Parameters on Lesion Size in Retinal Photocoagulation Surgery: Clinical OCT and Experimental Study

Introduction: The aim of the present study was to determine burn intensity in retinal laser photocoagulation based on laser parameters; wavelength, power, beam size and pulse duration, using Optical Coherence Tomography (OCT), fundus camera, physical eye model and computer simulation in a clinical study.Materials and Methods: Participants were 10 adult patients between 50-80 years with prolifer...

متن کامل

Optoacoustic real-time dosimetry for selective retina treatment.

The selective retina treatment (SRT) targets retinal diseases associated with disorders in the retinal pigment epithelium (RPE). Due to the ophthalmoscopic invisibility of the laser-induced RPE effects, we investigate a noninvasive optoacoustic real-time dosimetry system. In vitro porcine RPE is irradiated with a Nd:YLF laser (527 nm, 1.7-micros pulse duration, 5 to 40 microJ, 30 pulses, 100-Hz...

متن کامل

Selective retina therapy (SRT): a review on methods, techniques, preclinical and first clinical results.

Selective retina therapy (SRT) is a new laser procedure for retinal diseases that are thought to be associated with a degradation of the retinal pigment epithelium (RPE). The aim of the irradiation is to selectively damage the RPE without affecting the neural retina, the photoreceptors and the choroid. Goal of the treatment is to stimulate RPE cell migration and proliferation into the irradiate...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2008