Simplified diagnostic procedure for obstructive sleep apnoea syndrome: lower subsequent compliance with CPAP.

نویسندگان

  • J Krieger
  • E Sforza
  • C Petiau
  • T Weiss
چکیده

The aim of this study was to investigate whether a simplified diagnostic procedure based on ambulatory monitoring with MESAM IV altered subsequent compliance with continuous positive airway pressure (CPAP) in obstructive sleep apnoea (OSA) patients. During a period of 16 months, 60 patients with symptoms evocative of OSA and positive MESAM recording were prescribed CPAP after titration with standard polysomnography. Compliance was followed during 2 yrs based on built-in time counters and was compared with the compliance in two comparison groups: an equal number of equally severely affected patients diagnosed with standard polysomnography during the 18 months (8 months before and 8 months after) preceding and following the study period and a group of 48 patients with an estimated similar apnoea/hypopnoea index but less typical clinical and/or MESAM features, diagnosed as having OSA based on polysomnography during the study period. The three groups were not different by age, body mass index, or sleepiness score. Patients diagnosed with the ambulatory procedure had higher drop-out rates (21.7% versus 10% and 6.25%; p<0.05) and lower rates of use of their CPAP (43+/-0.3 h x night(-1)) than any of the control groups (53+/-0.2 and 5.6+/-0.2 h x night(-1), p<0.05). In conclusion, there is a risk that ambulatory diagnostic procedures alter the relationship of patients to their disease and/or the medical staff so that subsequent compliance with treatment may be decreased. The greatest care concerning compliance should be taken before an ambulatory-based diagnostic procedure is implemented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of three auto-adjusting positive pressure devices in patients with sleep apnoea.

Auto-adjustable continuous positive airway pressure (APAP) devices are an emerging treatment alternative to fixed-pressure continuous positive airway pressure (CPAP) therapy for obstructive sleep apnoea syndrome. They have been engineered to automatically adjust the pressure to the optimal level on a continuous basis. However, not all APAP technologies use the same algorithm. Three different AP...

متن کامل

Importance of sleep stage- and body position-dependence of sleep apnoea in determining benefits to auto-CPAP therapy.

The influence of sleep stage- and body position-dependence of sleep apnoea on treatment efficacy and compliance between conventional continuous positive airway pressure (CPAP) and auto CPAP therapy was evaluated. Thirty-three newly treated sleep apnoea hypopnoea syndrome (SAHS) patients were randomly allocated to conventional or auto-CPAP therapy. Six patients of each treatment group were class...

متن کامل

Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome.

Compliance with nasal continuous positive airway pressure (CPAP) has become a major concern, since this treatment is efficacious, but constraining. In 46 consecutive obstructive sleep apnoea (OSA) patients, we measured compliance with nasal CPAP by establishing a mean rate of use, with a built-in time counter read at three-month intervals, over a mean follow-up period of 232 +/- 27 days. The me...

متن کامل

Auto-adjusting versus fixed positive pressure therapy in mild to moderate obstructive sleep apnoea.

STUDY OBJECTIVES To determine if auto-adjusting positive airway pressure (APAP) would be better tolerated on the basis of delivering a lower mean pressure in patients with mild to moderate obstructive sleep apnoea syndrome (OSAS). DESIGN Patients spent 8 weeks on continuous positive airway pressure (CPAP) and 8 weeks on APAP in a randomized crossover design. SETTING Respiratory Sleep Disord...

متن کامل

Titrated mandibular advancement versus positive airway pressure for sleep apnoea.

The aim of this study was to compare mandibular advancement device (MAd) therapy and continuous positive airway pressure (CPAP) for obstructive sleep apnoea/hypopnoea syndrome (OSAHS) after one-night polysomnographic (PSG) titration of both treatments. 59 OSAHS patients (apnoea/hypopnoea index (AHI): 34+/-13 events x h(-1); Epworth scale: 10.6+/-4.5) were included in a crossover trial of 8 week...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 12 4  شماره 

صفحات  -

تاریخ انتشار 1998