Improving wavefront boundary condition for in vivo high resolution adaptive optics ophthalmic imaging
نویسندگان
چکیده
An ophthalmic adaptive optics (AO) imaging system is especially affected by pupil edge effects due to the higher noise and aberration level at the edge of the human pupil as well as the impact of head and eye motions on the pupil. In this paper, a two-step approach was proposed and implemented for reducing the edge effects and improving wavefront slope boundary condition. First, given an imaging pupil, a smaller size of sampling aperture can be adopted to avoid the noisy boundary slope data. To do this, we calibrated a set of influence matrices for different aperture sizes to accommodate pupil variations within the population. In step two, the slope data was extrapolated from the less noisy slope data inside the pupil towards the outside such that we had reasonable slope data over a larger aperture to stabilize the impact of eye pupil dynamics. This technique is applicable to any Neumann boundary-based active /adaptive modality but it is especially useful in the eye for improving AO retinal image quality where the boundary positions fluctuate.
منابع مشابه
In vivo fluorescent imaging of the mouse retina using adaptive optics.
In vivo imaging of the mouse retina using visible and near infrared wavelengths does not achieve diffraction-limited resolution due to wavefront aberrations induced by the eye. Considering the pupil size and axial dimension of the eye, it is expected that unaberrated imaging of the retina would have a transverse resolution of 2 microm. Higher-order aberrations in retinal imaging of human can be...
متن کاملAdaptive optics for ophthalmic applications using a pyramid wavefront sensor.
A new adaptive optics system for the eye using a pyramid wavefront sensor interfaced in closed-loop with a piezoelectric deformable mirror is presented. Sensing parameters such as CCD integration time, pupil sampling and beam steering amplitude are tested on the bench and in vivo on several volunteers to optimize real-time optical correction. The system allows closed-loop operation at a frame r...
متن کاملAdaptive optics with pupil tracking for high resolution retinal imaging
Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and...
متن کاملDual-thread parallel control strategy for ophthalmic adaptive optics.
To improve ophthalmic adaptive optics speed and compensate for ocular wavefront aberration of high temporal frequency, the adaptive optics wavefront correction has been implemented with a control scheme including 2 parallel threads; one is dedicated to wavefront detection and the other conducts wavefront reconstruction and compensation. With a custom Shack-Hartmann wavefront sensor that measure...
متن کاملAdaptive Optics Optical Coherence Tomography for in Vivo Retinal Imaging
Optical coherence tomography (OCT) is a non-invasive micrometer-resolution volumetric imaging modality that has been employed in diverse applications. In this thesis, we first describe a GPU accelerated program to perform FDOCT data processing and real time 3D volumetric rendering. The real time visualization of volumetric images provided by the GPU acceleration was essential to the rest of the...