PAS-Port® clampless proximal anastomotic device for coronary bypass surgery in porcelain aorta.
نویسندگان
چکیده
OBJECTIVES The severely calcified so-called porcelain aorta is one of the most dangerous and challenging findings in patients requiring coronary bypass surgery. Several techniques and technologies have been invented to handle this potentially lethal disease. We report on our initial experience with the PAS-Port® automated proximal clampless anastomotic device (Cardica, Inc., Redwood City, CA, USA), especially focussing on these patients. METHODS PAS-Port® anastomoses (for saphenous vein grafts) were performed in 17 patients undergoing coronary artery bypass graft (CABG) surgery. Of these, eight presented with the entity of porcelain aorta. In two patients, the diagnosis was previously known, in six cases heavily calcified aortas prohibiting any clamp manoeuvre were incidentally found intra-operatively. The site of anastomosis was determined by palpation and in individual cases with epi-aortic echocardiography. Other indications for PAS-Port® were localised dissection, acute myocardial infarction and partial sternotomy. Multislice computed tomography (CT) was performed in every patient to evaluate graft and anastomoses patency and appearance. RESULTS All 25 PAS-Port® anastomoses were triggered successfully. Two patients developed neurological deficits (prolonged reversible ischaemic neurological deficits, (PRIND)), with use of cardiopulmonary bypass (CPB) being the major predisposing factor (p=0.02). Graft patency could be affirmed in all grafts by multislice CT in all patients. CONCLUSIONS PAS-Port® anastomoses can be performed quickly, easily and, above all, safely in conditions prohibiting aortic clamping. Short-term results are excellent. Clear visualisation of anastomoses using multislice CT is an important advantage of the PAS-Port® device.
منابع مشابه
Six-month angiographic follow-up of the PAS-Port II clinical trial.
BACKGROUND The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. ...
متن کاملUse of skeletonized radial artery graft with the PAS-Port proximal anastomotic device.
PURPOSE We report our initial experience with the PAS-Port proximal anastomosis system (Cardica Inc, Redwood City, CA) using full-skeletonized radial artery (RA) in patients requiring off-pump coronary artery bypass grafting. DESCRIPTION The PAS-Port system (Cardica Inc) was used in 25 patients undergoing off-pump coronary artery bypass surgery. All patients received at least one RA graft usi...
متن کاملEvaluation of the PAS-Port Proximal Anastomosis System in coronary artery bypass surgery (the EPIC trial).
OBJECTIVE During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic...
متن کاملTwelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial. Invited commentary.
BACKGROUND The PAS-Port (Cardica Inc, Redwood City, CA) is an automated system that allows for the clampless anastomosis of vein grafts to the aorta. The intent of this study was to prospectively compare one year graft patency of this system with conventional hand-sewn anastomoses in a prospective, randomized trial. METHODS A total of 99 patients undergoing elective off-pump coronary bypass s...
متن کاملClampless off-pump coronary artery bypass prevents early post-operative neurologic injury compared to on-pump: a propensity score matched analysis
Background Unaortic coronary artery bypass with all arterial grafts proved to prevent early neurologic injury. Various devices for clampless proximal anastomosis of venous grafts were associated with an increased risk of microembolism. The Cardica PAS-Port is a new, fully automated device that might be able to obtain safe proximal aorto-venous connection without an increased risk of microor mac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 39 1 شماره
صفحات -
تاریخ انتشار 2011