Estimation of measurement error in plasma HIV-1 RNA assays near their limit of quantification

نویسندگان

  • Viviane D Lima
  • Lu Wang
  • Chanson Brumme
  • Lang Wu
  • Julio S G Montaner
  • P Richard Harrigan
چکیده

BACKGROUND Plasma HIV-1 RNA levels (pVLs), routinely used for clinical management, are influenced by measurement error (ME) due to physiologic and assay variation. OBJECTIVE To assess the ME of the COBAS HIV-1 Ampliprep AMPLICOR MONITOR ultrasensitive assay version 1.5 and the COBAS Ampliprep Taqman HIV-1 assay versions 1.0 and 2.0 close to their lower limit of detection. Secondly to examine whether there was any evidence that pVL measurements closest to the lower limit of quantification, where clinical decisions are made, were susceptible to a higher degree of random noise than the remaining range. METHODS We analysed longitudinal pVL of treatment-naïve patients from British Columbia, Canada, during their first six months on treatment, for time periods when each assay was uniquely available: Period 1 (Amplicor): 08/03/2000-01/02/2008; Period 2 (Taqman v1.0): 07/01/2010-07/03/2012; Period 3 (Taqman v2.0): 08/03/2012-30/06/2014. ME was estimated via generalized additive mixed effects models, adjusting for several clinical and demographic variables and follow-up time. RESULTS The ME associated with each assay was approximately 0.5 log10 copies/mL. The number of pVL measurements, at a given pVL value, was not randomly distributed; values ≤250 copies/mL were strongly systematically overrepresented in all assays, with the prevalence decreasing monotonically as the pVL increased. Model residuals for pVL ≤250 copies/mL were approximately three times higher than that for the higher range, and pVL measurements in this range could not be modelled effectively due to considerable random noise of the data. CONCLUSIONS Although the ME was stable across assays, there is substantial increase in random noise in measuring pVL close to the lower level of detection. These findings have important clinical significance, especially in the range where key clinical decisions are made. Thus, pVL values ≤250 copies/mL should not be taken as the "truth" and repeat pVL measurement is encouraged to confirm viral suppression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the artus HIV-1 QS-RGQ and VERSANT HIV-1 RNA 1.0 assays for quantitative detection of human immunodeficiency virus type 1 in plasma samples.

Several integrated diagnostic platforms to quantify human immunodeficiency virus type-1 viremia have been developed in recent years. We evaluated the performances of the Artus HIV-1 QS-RGQ assay, using the complete QIAsymphony RGQ workflow. 192 clinical plasma specimens and external control panel samples were analyzed, using the Artus assay and the routine Siemens VERSANT HIV-1 RNA 1.0 assay. T...

متن کامل

Quantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies

Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...

متن کامل

In vitro Evaluation of Biofield Treatment on Viral Load Against Human Immunodeficiency-1 and Cytomegalo Viruses

Viral load quantification is the amount of particular viral DNA or RNA in a blood samples. It is one of the surrogate biomarker of AIDS. High viral load indicates that the immune system is failed to fight against viruses. The aim of this study was to evaluate the impact of biofield treatment on HIV-1 and HCMV in terms of viral loads as surrogate marker. The viral load assay was performed on sto...

متن کامل

Dried blood spot HIV-1 RNA quantification: A useful tool for viral load monitoring among HIV-infected individuals in India

BACKGROUND & OBJECTIVES Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood s...

متن کامل

Human immunodeficiency virus type 1 (HIV-1) proviral DNA load in purified CD4+ cells by LightCycler® Real-time PCR

BACKGROUND The human immunodeficiency virus type 1 (HIV-1) proviral DNA persists in infected cells, even after prolonged successful HAART. In the present study, a relative quantification assay of HIV-1 proviral DNA by LightCycler real-time PCR based on SYBR Green I detection was developed in comparison to the number of purified CD4+ cells as estimated by the quantification of the beta-globin ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017