Cervical Pedicle Screw Placement Using Medial Funnel Technique
نویسندگان
چکیده
OBJECTIVE Cervical pedicle screw (CPS) placement is very challenging due to high risk of neurovascular complications. We devised a new technique (medial funnel technique) to improve the accuracy and feasibility of CPS placement. METHODS We reviewed 28 consecutive patients undergoing CPS instrumentation using the medial funnel technique. Their mean age was 51.4 years (range, 30-81 years). Preoperative diagnosis included degenerative disease (n=5), trauma (n=22), and infection (n=1). Screw perforations were graded with the following criteria: grade 0 having no perforation, grade 1 having <25%, grade 2 having 25%-50% and grade 3 having >50% of screw diameter. Grades 0 and 1 were considered as correct position. The degree of perforation was determined by 2 junior neurosurgeons and 1 senior neurosurgeon. RESULTS A total of 88 CPSs were inserted. The rate of correct placement was 94.3%; grade 0, 54 screws; grade 1, 29 screws; grade 2, 4 screws; and grade 3, 1 screw. No neurovascular complications or failure of instrumentation occurred. In perforated screws (34 screws), lateral perforations were 4 and medial perforations were 30. CONCLUSION We performed CPS insertion using medial funnel technique and achieved 94.3% (83 of 88) of correct placement. And it can decrease lateral perforation.
منابع مشابه
Biomechanical study of the funnel technique applied in thoracic pedicle screw replacement.
BACKGROUND Funnel technique is a method used for the insertion of screw into thoracic pedicle. AIM To evaluate the biomechanical characteristics of thoracic pedicle screw placement using the Funnel technique, trying to provide biomechanical basis for clinical application of this technology. METHODS 14 functional spinal units (T6 to T10) were selected from thoracic spine specimens of 14 fres...
متن کاملCervical Pedicle Screw Placement in Sawbone Models and Unstable Cervical Traumatic Lesions by Using Para-Articular Mini-Laminotomy: A Novice Neurosurgeon’s Experience
Cervical pedicle screw has been shown to provide stronger fixation than other methods. Due to these virtue of biomechanical characteristic, pedicle screw fixation can be used in a wide range of cervical spinal disorders, and excellent clinical results have been reported. However, this procedure is technically demanding because of the great variation in pedicle dimension and angulations between ...
متن کاملCervical pedicle screws: conventional versus computer-assisted placement of cannulated screws.
STUDY DESIGN Prospective clinical study with postoperative radiologic control of pedicle screw placement in the cervical spine. OBJECTIVES To evaluate whether cervical pedicle screws can be placed safely in a conventional technique when using cannulated screws and separate stab incisions. Also, to evaluate if accuracy and safety of pedicle screw placement can be improved using a computer-assi...
متن کاملAccuracy of the freehand technique for 3 fixation methods in the C-2 vertebrae.
OBJECT Intraoperative imaging often does not provide adequate visualization to ensure safe placement of screws. Therefore, the authors investigated the accuracy of a freehand technique for placement of pars, pedicle, and intralaminar screws in C-2. METHODS Sixteen cadaveric specimens were instrumented freehand by 2 experienced cervical spine surgeons with either a pars or pedicle screw, and b...
متن کاملA novel patient-specific navigational template for cervical pedicle screw placement.
STUDY DESIGN.: Prospective trial. OBJECTIVE.: To develop and validate a novel, patient-specific navigational template for cervical pedicle placement. SUMMARY OF BACKGROUND DATA.: Owing to the narrow bony anatomy and the proximity to the vertebral artery and the spinal cord, cervical instrumentation procedures demand the need for a precise technique for screw placement. PATIENT.: Specific drill ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2017