A disposable rotating oxygenator capable of being sterilized by heat for a heart-lung machine.

نویسندگان

  • M WILSON
  • K VOWLES
چکیده

This rotating oxygenator is of a design differing from other rotating oxygenators in that the large surface area necessary for filming blood at high rates of flow is obtained by using a small number of concentric drums rather than a large number of discs. This makes for simplicity of manufacture and ease of assembly. The design is such that it can be cast in plastic in three parts and mass produced at small cost. A number of plasti_s capable of being sterilized by heat are now available; preliminary tests of " araldite " (epoxide resin) suggest that it may be the most suitable for this purpose. A prototype has been machined out of perspex and has been us.d to test the design in regard to its oxygenating capacity and its effect on blood cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

نگرشی بر سیر تکاملی و کاربردهای بالینی اکسیژناتورها: گذشته، حال و آینده

Several therapeutic methods require an artificial lung (oxygenator) to replace the physiological function of lung. For instance, in some acute respiratory syndromes, the patient’s lungs are unable to perform their normal function and would need an assistive device to fulfill their performance. Moreover, in cardio-pulmonary bypass, when the heart has stopped pumping, blood is not sent to the lun...

متن کامل

A clinical report of the use of low-molecular-weight dextran in a rotating oxygenator.

Increasing use of heart-lung machines accentuates the desirability of reducing demands on blood donors by the addition of other priming fluids. Neptune, Bougas, and Panico (1960) described a machine requiring no priming blood, and Zuhdi, McCollough, Carey, Krieger, and Greer (1961) accepted haemodilution by 5% dextrose solution during hypothermic perfusion. Recently Long, Sanchez, Varco, and Li...

متن کامل

Total cardiopulmonary support with disposable membrane oxygenator during aortocoronary artery-vein graft operations.

Fifty-five patients received total cardiopulmonary support with the disposable Lande-Edwards membrane oxygenator during aortocoronary artery-vein graft operations and other complex open heart operations. Two three meter2 membrane oxygenators were linked in parallel to a standard r o b pump apparatus. (Three 3 meter2 membranes for patients weighing 80 to 103 kg.) Excellent oxygen and carbon diox...

متن کامل

Adult Perfusions using Rygg-Kyvsgaard Oxygenators

INTRODUCTION Rygg-Kyvsgaard oxygenators have been in constant clinical use for the past 15 years. • 2 ' 3 ' 4 ' 5 • 6 • 7 ' 8 • 9 • 10 The Harvey oxygenator is a new generation of disposable lung, based on an established principle, which incorporates an integral heat exchanger.n· 12 It was felt that a clinical comparison of a well established device with a new generation device would prove both...

متن کامل

Thermal Analysis of Laser Hardening for Different Moving Patterns

Transient thermal field in laser surface hardening treatment of medium carbon steel was analyzed by employing both three-dimensional analytical model and finite element model. In finite element model the laser beam was considered as a moving plane heat flux to establish the temperature rise distribution in the work-piece, while in analytical model laser beam was considered as an internal heat s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 15  شماره 

صفحات  -

تاریخ انتشار 1960