Precontoured locking plate fixation for displaced lateral clavicle fractures.

نویسندگان

  • Sang Ki Lee
  • Jae Won Lee
  • Dae Geon Song
  • Won Sik Choy
چکیده

Displaced fractures of the lateral end of the clavicle are associated with an increased risk of nonunion with conservative treatment; therefore, operative treatment is recommended. Various operative treatments have been suggested, but no consensus exists regarding a gold standard for the surgical treatment of this type of fracture. The purpose of this study was to evaluate clinical and radiological outcomes using a precontoured locking compressive distal clavicular plate for Neer type II distal clavicle fractures. Thirty-five patients with Neer type II distal clavicle fractures underwent surgery between March 2009 and January 2012. All patients were evaluated for function using the Constant-Murley Shoulder Outcome Score and University of California, Los Angeles shoulder rating scale, active shoulder range of motion, time to bone union, and coracoclavicular distance. Mean follow-up was 24.2 months (range, 12-35 months). No significant difference existed between the injured and contralateral sides in mean Constant-Murley scores (P=.13) or mean University of California, Los Angeles shoulder rating (P=.27). All patients obtained bony union over a mean of 4.1 months (range, 3.5-6.0 months).The coracoclavicular distance was not significantly different between the injured and contralateral shoulders in the immediate postoperative period (P=.28) or at final follow-up (P=.35). One superficial wound infection occurred, but no major complications, such as nonunion, plate failure, secondary fracture, or deep infection, occurred. Precontoured locking compressive distal clavicular plate fixation for the treatment of displaced fractures of the lateral end of the clavicle is an acceptable surgical method with good results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomically precontoured LCP for delayed union of a medial third clavicle fracture. Case report with review of the literature.

BACKGROUND Fractures of the medial clavicle third are rare injuries. Even in case of significant fracture displacement, their therapeutic management has been nonoperative. Recently, surgical intervention has become mandatory for displaced fractures types to prevent non-union and functional complaints, but the optimal operative strategy is being discussed controversially. CASE PRESENTATION We ...

متن کامل

Use of a real-size 3D-printed model as a preoperative and intraoperative tool for minimally invasive plating of comminuted midshaft clavicle fractures

BACKGROUND Open reduction and plate fixation is the standard operative treatment for displaced midshaft clavicle fracture. However, sometimes it is difficult to achieve anatomic reduction by open reduction technique in cases with comminution. METHODS We describe a novel technique using a real-size three dimensionally (3D)-printed clavicle model as a preoperative and intraoperative tool for mi...

متن کامل

Precontoured Locking Plate Treatment in Mid-Shaft Clavicle Fractures: Outcomes and Complications with a Minimun of 2- Years Follow up

Background: The aim of this study was to evaluate functional outcome and complications with a long term followup (minimum of 2 years post-operative) in patients with mid-shaft clavicle fractures treated with precontoured lockingplates.Methods: We included 41 patients. Goniometric measurement of shoulder range of motion (ROM) was performed,as well as functional evaluation using the rating scale ...

متن کامل

Unicortical versus bicortical locked plate fixation in midshaft clavicle fractures.

Higher rates of poor outcomes in displaced midshaft clavicle fractures treated nonoperatively have recently been reported. Along with expanding indications for operative fixation and increasing application of locked plate constructs, it is unknown whether complications related to bicortical penetration of the clavicle can be avoided using unicortical fixation. The purpose of this study is to co...

متن کامل

Comparison of complication rates of intramedullary pin fixation versus plating of midshaft clavicle fractures in an active duty military population.

Military service members have increased requirements of shoulder weight bearing to perform duties. Operative intervention has increased for treatment of displaced middle one-third clavicle fractures. Complications of operatively treated clavicle fixation have not been extensively studied. A retrospective, longitudinal cohort chart evaluation was conducted of all active duty members undergoing f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 36 6  شماره 

صفحات  -

تاریخ انتشار 2013