Investigation of slice excitation using transmit arrays and non-selective RF pulses
نویسندگان
چکیده
[1] P. Börnert, and T. Schaffter, MRM, vol. 36, no. 6, pp. 932-9, Dec, 1996 [2] T. H. Jochimsen, and D. G. Norris, Magma, vol. 14, no. 1, pp. 50-5, Mar, 2002 [3] U. Katscher, and P. Bornert, NMR Biomed, vol. 19, no. 3, pp. 393-400, May, 2006 [4] P. Ullmann, S. Junge, M. Wick et al., MRM, vol. 54, no. 4, pp. 994-1001, Oct, 2005 [5] Y. Zhu, MRM, vol. 51, no. 4, pp. 775-84, Apr, 2004 [6] M. P. McDougall, and S. M. Wright, MRM, vol. 54, no. 2, pp. 386-92, Aug, 2005 [7] Y.T.Lo, Ant Eng Handbook, 1 ed., H. Jasik, Ed. New York: McGraw-Hill, 1961, pp. 10-24. [8] Y.T. Lo, S.M. Wright, J.A. Navarro, and M. Davidovitz, Handbook of RF/Microwave Components and Engineering, Kai Chang, Ed. New York:Wiley 2003 [9] M. P. McDougall, J. M. Knight, E. E. Eigenbrodt et al. Conf Proc IEEE Eng Med Biol Soc, vol. 2008, pp. 2043-6, 2008 [10] X. Chen, et al., in 17th Annual Meeting of the ISMRM, 2008, pp. 1140 [11] K. Feng et al., in 17th Annual Meeting of the ISMRM, 2009, pp. 3021
منابع مشابه
Fast slice-selective radio-frequency excitation pulses for mitigating B+1 inhomogeneity in the human brain at 7 Tesla.
A novel radio-frequency (RF) pulse design algorithm is presented that generates fast slice-selective excitation pulses that mitigate B+1 inhomogeneity present in the human brain at high field. The method is provided an estimate of the B+1 field in an axial slice of the brain and then optimizes the placement of sinc-like "spokes" in kz via an L1-norm penalty on candidate (kx, ky) locations; an R...
متن کاملZ-stacked RF array design enhances parallel transmit multiband RF performance in whole brain simultaneous multislice imaging at 7T
Introduction: Simultaneous MultiSlice (SMS) MR imaging (1) using MultiBand (MB) RF pulses is becoming increasingly popular in the neuroimaging community (2-4). Recently, there has been an interest in utilizing multielement RF arrays in combination with multichannel (pTx) MB pulse design to reduce transmit B1 (B1+) inhomogeneity and SAR (5,6) for SMS/MB imaging. Meanwhile, it has been shown that...
متن کاملParallel Transmit Technology for High Field MRI
The success of parallel reconstruction methods and their impact on image encoding has sparked a great deal of interest in using the spatial distribution of transmit coils in an analogous fashion. Namely, by breaking down the transmit field into multiple regions each controlled by a separate transmit channel, spatial degrees of freedom are created that allow the spatial information in the array ...
متن کاملArray-compressed parallel transmit pulse design.
PURPOSE To design array-compressed parallel transmit radiofrequency (RF) pulses and compare them to pulses designed with existing transmit array compression strategies. THEORY AND METHODS Array-compressed parallel RF pulse design is proposed as the joint optimization of a matrix of complex-valued compression weights that relate a full-channel physical array to a reduced-channel virtual array,...
متن کاملB1 mapping of an 8-channel TX-array over a human-head-like volume in less than 2 minutes: the XEP sequence
Introduction: Efficient mitigation of the RF inhomogeneity at high field using transmit coil arrays relies on the knowledge of the individual B1 maps. As the number of transmit channels increases, so does the acquisition time of all maps. For in-vivo experiments, it is crucial to minimize this time of calibration, and several B1measuring techniques compete to reach that goal. Here we focus on a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2009