Clinical outcomes of patients treated with Nobori biolimus-eluting stent: Meta-analysis of randomized trials.

نویسندگان

  • Salvatore Cassese
  • Massimiliano Fusaro
  • Robert A Byrne
  • Tomohisa Tada
  • Petra Hoppmann
  • Michael Joner
  • Karl-Ludwig Laugwitz
  • Heribert Schunkert
  • Adnan Kastrati
چکیده

BACKGROUNDS The Nobori is a new-generation, biodegradable-polymer coated, biolimus-eluting stent (BES) that has recently been investigated in several randomized trials with inconsistent results. The aim of this study was to assess the efficacy and safety of Nobori BES versus other drug-eluting stents (DES) in patients treated with percutaneous coronary intervention (PCI). METHODS We undertook a meta-analysis of randomized trials investigating Nobori BES versus other DES. Primary efficacy and safety outcomes were target lesion revascularization (TLR) and definite/probable stent thrombosis (ST), respectively. Secondary outcomes were the composite of cardiac death/myocardial infarction (MI)/target vessel revascularization (TVR), MI and death. RESULTS A total of 9114 PCI-patients randomly received Nobori BES (n=5080) or other DES (n=4034). This latter group comprised patients receiving everolimus- (n=2533), sirolimus- (n=1376) or paclitaxel-eluting stents (n=125). Median follow-up was 11 months [interquartile range 9-12]. The Nobori BES versus other DES showed comparable risk of TLR (odds ratio [95% confidence interval]=0.91 [0.57-1.46], p=0.71). There was significant heterogeneity across trials due to significant lower TLR risk with Nobori BES versus paclitaxel-eluting stent (0.32 [0.10-0.98], p=0.046; p for interaction=0.009). Nobori BES versus other DES showed comparable risk of definite/probable ST (1.40 [0.66-2.97], p=0.39), cardiac death/MI/TVR (1.05 [0.88-1.25], p=0.59), MI (1.13 [0.87-1.48], p=0.37) and death (1.09 [0.81-1.48], p=0.56). CONCLUSIONS Nobori BES has comparable efficacy with other limus-eluting stents at 1-year follow-up. There is no difference in terms of safety profile between these stent platforms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Randomized Comparison of a Biodegradable Polymer Ultrathin Strut Sirolimus-Eluting Stent With a Biodegradable Polymer Biolimus-Eluting Stent in Patients Treated With Percutaneous Coronary Intervention

In percutaneous coronary interventions, drug-eluting stents (DESs) have reduced the risk of restenosis and repeat revascularization compared with bare-metal stents. The secondgeneration DESs with thinner stent struts have improved safety and efficacy compared with the first-generation DESs and has been associated with a reduced risk of late stent thrombosis. The persistence of polymer material ...

متن کامل

Clinical Impact of Intravascular Ultrasound-Guided Chronic Total Occlusion Intervention With Zotarolimus-Eluting Versus Biolimus-Eluting Stent Implantation: Randomized Study.

BACKGROUND There have been no randomized studies comparing intravascular ultrasound (IVUS)-guided versus conventional angiography-guided chronic total occlusion (CTO) intervention using new-generation drug-eluting stent Therefore, we conducted a prospective, randomized, multicenter trial designed to test the hypothesis that IVUS-guided CTO intervention is superior to angiography-guided interven...

متن کامل

Nobori-Biolimus-Eluting Stents versus Resolute Zotarolimus-Eluting Stents in Patients Undergoing Coronary Intervention: A Propensity Score Matching

PURPOSE To compare the 1-year outcomes of a durable polymer Zotarolimus-eluting stent (ZES) versus a biodegradable polymer Biolimus-eluting stent (BES) in patients undergoing percutaneous coronary intervention. MATERIALS AND METHODS A total of 2083 patients from 2 different registries, 1125 treated with BES in NOBORI registry and 858 received ZES in CONSTANT registry were included in this stu...

متن کامل

Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial.

BACKGROUND Third-generation biodegradable polymer drug-eluting stents might reduce the risk of stent thrombosis compared with first-generation permanent polymer drug-eluting stents. We aimed to further investigate the effects of a biodegradable polymer biolimus-eluting stent compared with a durable polymer-coated sirolimus-eluting stent in a population-based setting. METHODS This randomised, ...

متن کامل

Optical Coherence Tomography Guided Percutaneous Coronary Intervention With Nobori Stent Implantation in Patients With Non-ST-Segment-Elevation Myocardial Infarction (OCTACS) Trial: Difference in Strut Coverage and Dynamic Malapposition Patterns at 6 Months.

BACKGROUND Incomplete strut coverage has been documented an important histopathologic morphometric predictor for later thrombotic events. This study sought to investigate whether optical coherence tomography (OCT)-guided percutaneous coronary intervention with Nobori biolimus-eluting stent implantation in patients with non-ST-segment-elevation myocardial infarction would provide improved strut ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of cardiology

دوره 175 3  شماره 

صفحات  -

تاریخ انتشار 2014