Determination of perchlorate in drinking water by ion chromatography using macrocycle-based concentration and separation methods.

نویسندگان

  • John D Lamb
  • David Simpson
  • Bryce D Jensen
  • Joseph S Gardner
  • Quinn P Peterson
چکیده

Macrocycle-based ion chromatography provides a convenient, reliable method for the determination of perchlorate ion, which is currently of great interest to the environmental community. This study shows that effective perchlorate determinations can be made using standard conductimetric detection by combining an 18-crown-6-based mobile phase with an underivatized reversed-phase mobile phase ion chromatography (MPIC) column. One unique feature of this method is the flexibility in column capacity that is achieved through simple variations in eluent concentrations of 18-crown-6 and KOH, facilitating the separation of target analyte anions such as perchlorate. Using a standard anion exchange column as concentrator makes possible the determination of perchlorate as low as 0.2 ug/L in low ionic strength matrices. Determination of perchlorate at the sub-ug/L level in pure water and in spiked local city hard water samples with high background ion concentrations can be achieved this way. However, like other IC techniques, this method is challenged to achieve analyses at the ug/L level in the demanding high ionic strength matrix described by the United States Environmental Protection Agency (EPA) (1,000 mg/L chloride, sulfate and carbonate). We approached this challenge by use of the Cryptand C1 concentrator column, provided by Dionex Corporation, to effectively preconcentrate perchlorate while reducing background ion concentrations in the high ionic strength matrix. The retention characteristics of the concentrator column were studied in order to maximize its effectiveness for perchlorate determinations. The method makes possible the determination of perchlorate at the 5 ug/L level in the highest ionic strength matrix described by the EPA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection

BACKGROUND Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlora...

متن کامل

Determination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry.

Perchlorate has been added to the U.S. Environmental Protection Agency's Drinking Water Contaminant Candidate List (CCL). The present work describes the analysis of perchlorate in water by liquid-liquid extraction followed by flow injection electrospray mass spectrometry (ESI/MS). Cationic surfactants, mostly alkyltrimethyl-ammonium salts, are used to ion-pair aqueous perchlorate, forming extra...

متن کامل

تعیین غلظت پرکلرات در آب و خاک سطحی مناطق جنگی (مطالعه موردی: شهرستان خرمشهر)

Background and Objectives: Perchlorate, as an emerging contaminant, has attracted notice of the most individuals and organizations. Presence of perchlorate in the human body can lead to inappropriate regulation of metabolism in adults. Moreover, due to inhibition of iodide uptake in the thyroid gland, it causes neurological and behavioral problems in infants and children. United States Environm...

متن کامل

Microscale extraction of perchlorate in drinking water with low level detection by electrospray-mass spectrometry.

Improper treatment and disposal of perchlorate can be an environmental hazard in regions where solid rocket motors are used, tested, or stored. The solubility and mobility of perchlorate lends itself to ground water contamination, and some of these sources are used for drinking water. Perchlorate in drinking water has been determined at sub-mug l(-1) levels by extraction of the ion-pair formed ...

متن کامل

Determination of trace levels of haloacetic acids and perchlorate in drinking water by ion chromatography with direct injection.

Disinfection by products of haloacetic acids and perchlorate pose significant health risks, even at low microg/l levels in drinking water. A new method for the simultaneous determination of nine haloacetic acids (HAAs) and perchlorate as well as some common anions in one run with ion chromatography was developed. The HAAs tested included mono-, di-, trichloroacetic acids, mono, di-, tribromoace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1118 1  شماره 

صفحات  -

تاریخ انتشار 2006