Comparison of a Resonant Mirror Biosensor (IAsys) and a Quartz Crystal Microbalance (QCM) for the Study on Interaction between Paeoniae Radix 801 and Endothelin-1

نویسندگان

  • Jiadong Huang
  • Qing Lin
  • Jinghua Yu
  • Shenguang Ge
  • Jing Li
  • Min Yu
  • Zixia Zhao
  • Xinsheng Wang
  • Xiuming Zhang
  • Xiaorui He
  • Liang Yuan
  • Huijun Yin
  • Tetsuo Osa
  • Keji Chen
  • Qiang Chen
چکیده

A resonant mirror biosensor, IAsys, and a quartz crystal microbalance (QCM) are known independently as surface sensitive analytical devices capable of label-free and in situ bioassays. In this study, an IAsys and a QCM are employed for a new study on the action mechanism of Paeoniae Radix 801 (P. radix 801) by detecting the specific interaction between P. radix 801 and endothelin-1 (ET-1). In the experiments, ET-1 was immobilized on the surfaces of the IAsys cuvette and the QCM substrate by surface modification techniques, and then P. radix 801 solution was contacted to the cuvette and the substrate, separately. Then, the binding and interaction process between P. radix 801 and ET-1 was monitored by IAsys and QCM, respectively. The experimental results showed that P. radix 801 binds ET-1 specifically. The IAsys and QCM response curves to the ET-1 immobilization and P. radix 801 binding are similar in reaction process, but different in binding profiles, reflecting different resonation principles. Although both IAsys and QCM could detect the interaction of P. radix 801 and ET-1 with high reproducibility and reliability through optimization of the ET-1 coating, the reproducibility and reliability obtained by IAsys are better than those obtained by QCM, since the QCM frequency is more sensitive to temperature fluctuations, atmospheric changes and mechanical disturbances. However, IAsys and QCM are generally potent and reliable tools to study the interaction of P. radix 801 and ET-1, and can conclusively be applied to the action mechanism of P. radix 801.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Fibrinogen and Coagulation Factor VIII in Plasma by a Quartz Crystal Microbalance Biosensor

A quartz crystal microbalance (QCM) biosensor with nanogram sensitivity has been constructed through a reasonable designing and biological processing of the piezoelectric quartz crystals. Due to its highly sensitivity, real time detection and low cost, the proposed QCM biosensor has a promising potential in blood coagulation research. In the current study, the QCM biosensor was used to determin...

متن کامل

Quartz Crystal Microbalance Study of Dna Immobilization and Hybridization for Dna Sensor Development

Piezoelectric materials such as quartz can be used to detect mass change due to their piezoelectric properties. Quartz Crystal Microbalance (QCM) is an extremely sensitive mass sen frequency biosensor mass mea for QCM DNA biosensor was developed. The potential for QCM to be employed as immunosensor sor, capable of measuring sub-nanogram levels by detecting change in the of a quartz crystal reso...

متن کامل

A Novel Cell-Based Hybrid Acoustic Wave Biosensor with Impedimetric Sensing Capabilities

A novel multiparametric biosensor system based on living cells will be presented. The biosensor system includes two biosensing techniques on a single device: resonant frequency measurements and electric cell-substrate impedance sensing (ECIS). The multiparametric sensor system is based on the innovative use of the upper electrode of a quartz crystal microbalance (QCM) resonator as working elect...

متن کامل

Kinetic characterization of the retinoic X receptor binding to specific and unspecific DNA oligoduplexes with a quartz crystal microbalance.

Quartz Crystal Microbalance (QCM) biosensor technology was used to study the interaction of the DNA-binding domain (DBD) of the transcription factor RXRα with immobilized specific (DR1) and unspecific (DR1neg) DNA oligoduplexes. We identify the QCM sensor frequency at the susceptance minimum (fBmin) as a better measuring parameter, and we show that fBmin is proportional to the mass adsorbed at ...

متن کامل

In situ QCM DNA-biosensor probe modification

We report on a probe modification of a quartz crystal microbalance (QCM) DNA-biosensor that permits to reversibly change the DNA sequence detected. A QCM DNA-biosensor was designed by immobilization of a 20-base DNA-disulfide probe on the gold-covered quartz surface of a 27 MHz microbalance (9 MHz, third overtone). After immobilization on the gold covered quartz surface, this probe was modified...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2008