The Challenge of Assigning General Ventilation Rates in Labs
نویسندگان
چکیده
In a previous article, we described how we used two ANSI standards (Z10 and Z9.5) to develop an institutional Laboratory Ventilation Management Program (LVMP). This paper describes our use of a control banding strategy as a key tool in this LVMP to establish target ventilation rates for specific laboratory spaces. In spaces where chemicals are used consistent with OSHA’s definition of laboratories, Cornell University in Ithaca, NY uses a default rate of 8 air changes per hour (ACH) when the lab is occupied and 4 ACH when the lab is unoccupied. The primary alternative control band for laboratory ventilation, when conditions allow, is 6 ACH (occupied) and 3 ACH (unoccupied). These ranges are used when three operating conditions are met: volatile chemical sources are controlled by local ventilation; the ventilation effectiveness within the laboratory prevents accumulation of significant concentrations of chemical vapors; and laboratory housekeeping is adequate to avoid ongoing sources of fugitive emissions in the laboratory. In this process, we also identify laboratory chemical uses that lie outside these control bands; these require specialized review to determine appropriate ventilation rates.
منابع مشابه
تأثیر تهویه با حجمهای جاری متفاوت و تهویه دقیقهای ثابت بر روی دیاکسید کربن انتهای بازدمی
Background & Aims: Elimination of carbon dioxide is related to the alveolar ventilation, respiratory rate and tidal volume. The aim of this study to determine the effect of mechanical ventilation with different tidal volumes and constant minute ventilation on the end tidal Co2 and oxygen saturation during general anesthesia and to seek optimum parameters of mechanical ventilation during gener...
متن کاملA Randomized Clinical Trial to Compare the Criteria of Readiness for Extubation and Daily Spontaneous Breathing Test (SBT) on the Duration of Mechanical Ventilation
Background: Successful weaning of the ventilator is a major challenge, especially in children. This study was conducted to compare the criteria of readiness for extubation and daily spontaneous breathing test (SBT) on the duration of mechanical ventilation and extubation failure rates. Materials and Metho...
متن کاملAssessing general ventilation effectiveness in the laboratory
The goal of a laboratory’s general ventilation system is to control airborne contaminants below concentrations of concern while maintaining a comfortable environment. One concern while managing general laboratory ventilation is how uniformly the room is ventilated. We have observed that, depending on the configuration of the ventilation supply and exhaust points relative to the geometry of the ...
متن کاملارزیابی کیفی عملکرد تهویه موضعی در آزمایشگاه های یک شرکت پتروشیمی جهت کاهش مواجهه کارکنان
Background & Objectives : Chemicals are serious harmful agents in the workplace, especially chemistry labs. This material may cause poisoning and different diseases. Laboratory hoods as first safety device protect laboratory workers against hazardous chemicals. This research conducted on chemistry labs in a petrochemical company for awareness of the hoods performance and proposed the nee...
متن کاملThe impacts of prone position on the blood oxygen saturations and heart rates of preterm infants under the mechanical ventilation
Background: The methods of baby's position are an important critical factor in ventilation and oxygenation of tissues. Although the prone position as one of the recommended position has beneficial effect on the development of premature infants, little research has been done. Methods: In a clinical trial among mechanically ventilated infants, hospitalized in the neonatal intensive care units (N...
متن کامل