Evaluation of depth of cure and knoop hardness in a dental composite, photo-activated using different methods

نویسندگان

  • Mithra N Hegde
  • Priyadarshini Hegde
  • Babita Malhan
چکیده

The study aimed at evaluating the depth of cure and knoop hardness of a microfine-hybrid composite resin that was photo-activated using different methods. A bipartite brass mold was filled with composite resin and photo-activation was performed using four methods: (1) Intermittent method using quartz tungsten halogen (QTH) light curing unit (LCU) (2) Continuous method (QTH) (3) Exponential method (QTH) (4) Continuous method using light-emitting diode (LED). Depth of cure was measured at the unexposed bottom surface of the specimen using microtester as a penetrometer. The surfaces exposed to light were subjected to knoop hardness testing, using a digital microhardness tester. Knoop hardness measurements were obtained at the top surface and at depths of 1, 2, 3, 4 and 5 mm. The data was analyzed using anova and Tukey's test (5%). Results showed that the depth of cure was higher with the intermittent method (QTH), followed by the continuous method (QTH), the exponential method and the continuous method (LED). At the top surface and up to 1 mm, continuous method (LED) demonstrated the highest knoop hardness number (KHN). At 2 mm and up to 5 mm, intermittent method (QTH) presented the highest KHN and continuous method (LED) showed the lowest KHN. At all depths, continuous method (QTH) showed higher KHN, as compared to the exponential method (QTH), except at 2 mm where both showed no significant difference.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of a translucent post on resin composite depth of cure.

OBJECTIVE To evaluate the effect of a light-transmitting post on the depth of cure of a resin composite. METHODS Acetate resin molds were filled with resin composite in which a light-transmitting post was inserted into the center and photopolymerized to the manufacturer's recommendations. Identical molds without a light-transmitting post were photopolymerized in a similar matter and served as...

متن کامل

Depth of cure and hardness of an indirect composite polymerized with three laboratory curing units.

This study determined the hardness and curing depth of a light-activated indirect composite polymerized with three laboratory light-polymerizing units for the purpose of comparing the curing performance of the three units. A light-activated composite material for indirect application (Vita Zeta) was polymerized with three light-polymerizing units equipped with the following light sources: 1) on...

متن کامل

Impact of refrigeration on the surface hardness of hybrid and microfilled composite resins.

This in vitro study evaluated the Knoop hardness of the composite resins Charisma (C) and Durafill VS (D) polymerized in 3 different conditions: at room temperature (A) (23 +/- 1 degrees C); refrigerated at 4 +/- 1 degrees C and immediately photo-activated after removal from the refrigerator (0); and, refrigerated at 4 +/- 1 degrees C and photo-activated after a bench time of 15 min at room tem...

متن کامل

Effect of preliminary irradiation on depth of cure and hardness of a veneering composite.

This study evaluated the effect of preliminary irradiation on the depth of cure and Knoop hardness of a veneering composite. The composite was filled into a mold, and irradiated with different irradiation duration or irradiance. After removing the mold, the depth of cure was measured, and the Knoop hardness number at each depth was determined and statistically analyzed using Mann-Whitney U test...

متن کامل

Depth of cure and hardness of indirect composite materials polymerized with two metal halide laboratory curing units.

The purpose of this study was to evaluate the depth of cure and Knoop hardness of indirect composite materials polymerized with different laboratory curing units. Five composite materials designed for fixed restoration veneer (Artglass, Ceramage, Epricord, Prossimo, and Solidex) were filled into a cylindrical mold and then light-exposed by using the respective proprietary laboratory curing unit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2004