Airflow Uniformity through Perforated Tiles in a Raised-Floor Data Center

نویسندگان

  • James W. VanGilder
  • Roger R. Schmidt
چکیده

The maximum equipment power density (e.g. in power/rack or power/area) that may be deployed in a typical raised-floor data center is limited by perforated tile airflow. In the design of a data center cooling system, a simple estimate of mean airflow per perforated tile is typically made based on the number of CRAC’s and number of perforated tiles (and possibly a leakage airflow estimate). However, in practice, many perforated tiles may deliver substantially more or less than the mean, resulting in, at best, inefficiencies and, at worst, equipment failure due to inadequate cooling. Consequently, the data center designer needs to estimate the magnitude of variations in perforated tile airflow prior to construction or renovation. In this paper, over 240 CFD models are analyzed to determine the impact of data-center design parameters on perforated tile airflow uniformity. The CFD models are based on actual data center floor plans and the CFD model is verified by comparison to experimental test data. Perforated tile type and the presence of plenum obstructions have the greatest potential influence on airflow uniformity. Floor plan, plenum depth, and airflow leakage rate have modest effect on uniformity and total airflow rate (or average plenum pressure) has virtually no effect. Good uniformity may be realized by using more restrictive (e.g. 25%open) perforated tiles, minimizing obstructions and leakage airflow, using deeper plenums, and using rectangular floor plans with standard hot aisle/cold aisle arrangements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cfd Simulations Comparing Hard Floor and Raised Floor Configurations in an Air Cooled Data Center

An increasing number of companies and organisations have started to outsource their data storage. Although the potential of future investments in data centers is prosperous, sustainability is an increasingly important factor. It is important to make sure that the server racks in data centers are sufficiently cooled whereas too much forced cooling leads to economical losses and a waste of energy...

متن کامل

Simulation of Thermal Distribution and Airflow for Efficient Energy Consumption in a Small Data Centers

Data centers have become ubiquitous in the last few years in an attempt to keep pace with the processing and storage needs of the Internet and cloud computing. The steady growth in the heat densities of IT servers leads to a rise in the energy needed to cool them, and constitutes approximately 40% of the power consumed by data centers. However, many data centers feature redundant air conditioni...

متن کامل

Altered nasal airflow: an unusual complication following implant surgery in the anterior maxilla

Dental implants have been in routine clinical use for over three decades and are a predictable treatment modality. However, as with all other aspects of dentistry, complications occur. A 50-year-old female patient with complaints of a long ongoing unpleasant altered nasal airflow presented herself at the VU University Medical Center Amsterdam. Visual inspection of the right nasal cavity reveale...

متن کامل

Comparison of airflow and contaminant distributions in rooms with traditional displacement ventilation and under-floor air distribution systems

Traditional displacement ventilation (TDV) and under-floor air distribution (UFAD) systems have been used widely because they create better indoor air quality. Many previous studies have compared the TDV or UFAD systems with mixing ventilation systems. This study first compared experimentally the TDV with UFAD systems that use four different diffusers (perforated TDV diffusers, swirl diffusers,...

متن کامل

CFD-Based Operational Thermal Efficiency Improvement of a Production Data Center

Effective cooling of data centers presents a dual challenge: increased cooling power to meet the ever increasing device heat loads, and the need for energy efficient cooling. Detailed analysis of the thermal and flow conditions within a data center are necessary for obtaining optimal design and operational parameters. This paper describes the application of a computational fluid dynamics (CFD) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011