Inverse Z-spectrum analysis for spillover-, MT-, and T1 -corrected steady-state pulsed CEST-MRI--application to pH-weighted MRI of acute stroke.

نویسندگان

  • Moritz Zaiss
  • Junzhong Xu
  • Steffen Goerke
  • Imad S Khan
  • Robert J Singer
  • John C Gore
  • Daniel F Gochberg
  • Peter Bachert
چکیده

Endogenous chemical exchange saturation transfer (CEST) effects are always diluted by competing effects, such as direct water proton saturation (spillover) and semi-solid macromolecular magnetization transfer (MT). This leads to unwanted T2 and MT signal contributions that lessen the CEST signal specificity to the underlying biochemical exchange processes. A spillover correction is of special interest for clinical static field strengths and protons resonating near the water peak. This is the case for all endogenous CEST agents, such as amide proton transfer, -OH-CEST of glycosaminoglycans, glucose or myo-inositol, and amine exchange of creatine or glutamate. All CEST effects also appear to be scaled by the T1 relaxation time of water, as they are mediated by the water pool. This forms the motivation for simple metrics that correct the CEST signal. Based on eigenspace theory, we propose a novel magnetization transfer ratio (MTRRex ), employing the inverse Z-spectrum, which eliminates spillover and semi-solid MT effects. This metric can be simply related to Rex , the exchange-dependent relaxation rate in the rotating frame, and ka , the inherent exchange rate. Furthermore, it can be scaled by the duty cycle, allowing for simple translation to clinical protocols. For verification, the amine proton exchange of creatine in solutions with different agar concentrations was studied experimentally at a clinical field strength of 3 T, where spillover effects are large. We demonstrate that spillover can be properly corrected and that quantitative evaluation of pH and creatine concentration is possible. This proves that MTRRex is a quantitative and biophysically specific CEST-MRI metric. Applied to acute stroke induced in rat brain, the corrected CEST signal shows significantly higher contrast between the stroke area and normal tissue, as well as less B1 dependence, than conventional approaches.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inverse Z-spectrum analysis for clean NOE and amide CEST-MRI – application to human glioma

Inverse Z-spectrum analysis for clean NOE and amide CEST-MRI – application to human glioma Moritz Zaiss, Johannes Windschuh, Jan-Eric Meissner, Daniel Paech, Alexander Radbruch, and Peter Bachert Dept. Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany, Dept. of Neuroradiology, University of Heidelberg, Heidelberg, Germany, Section Neuro–oncologic Imaging, G...

متن کامل

Analytical determination of the chemical exchange saturation transfer (CEST) contrast in molecular magnetic resonance imaging

Magnetic resonance based on molecular imaging allows tracing contrast agents thereby facilitating early diagnosis of diseases in a non-invasive fashion that enhances the soft tissue with high spatial resolution. Recently, the exchange of protons between the contrast agent and water, known as the chemical exchange saturation transfer (CEST) effect, has been measured by applying a suitable pulse ...

متن کامل

Z-spectrum asymmetry : from 3T to 7T

Introduction: Magnetization Transfer and technically related effects such as CEST are important sources of contrast in MRI. Studying MT in vivo at 7T is challenging due to the increase in longitudinal relaxation time and SAR limits. To overcome this, we use pulsed saturation with EPI readout (MT-EPI) to measure MT at a range of offset frequencies and on the approach to steady-state in a reasona...

متن کامل

Fast multislice pH-weighted chemical exchange saturation transfer (CEST) MRI with Unevenly segmented RF irradiation.

Chemical exchange saturation transfer (CEST) MRI is a versatile imaging technique for measuring microenvironment properties via dilute CEST labile groups. Conventionally, CEST MRI is implemented with a long radiofrequency irradiation module, followed by fast image acquisition to obtain the steady state CEST contrast. Nevertheless, the sensitivity, scan time, and spatial coverage of the conventi...

متن کامل

Chemical exchange saturation transfer (CEST) and MR Z-spectroscopy in vivo: a review of theoretical approaches and methods.

Chemical exchange saturation transfer (CEST) of metabolite protons that undergo exchange processes with the abundant water pool enables a specific contrast for magnetic resonance imaging (MRI). The CEST image contrast depends on physical and physiological parameters that characterize the microenvironment such as temperature, pH, and metabolite concentration. However, CEST imaging in vivo is a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NMR in biomedicine

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2014