An On-Chip RBC Deformability Checker Significantly Improves Velocity-Deformation Correlation
نویسندگان
چکیده
An on-chip deformability checker is proposed to improve the velocity–deformation correlation for red blood cell (RBC) evaluation. RBC deformability has been found related to human diseases, and can be evaluated based on RBC velocity through a microfluidic constriction as in conventional approaches. The correlation between transit velocity and amount of deformation provides statistical information of RBC deformability. However, such correlations are usually only moderate, or even weak, in practical evaluations due to limited range of RBC deformation. To solve this issue, we implemented three constrictions of different width in the proposed checker, so that three different deformation regions can be applied to RBCs. By considering cell responses from the three regions as a whole, we practically extend the range of cell deformation in the evaluation, and could resolve the issue about the limited range of RBC deformation. RBCs from five volunteer subjects were tested using the proposed checker. The results show that the correlation between cell deformation and transit velocity is significantly improved by the proposed deformability checker. The absolute values of the correlation coefficients are increased from an average of 0.54 to 0.92. The effects of cell size, shape and orientation to the evaluation are discussed according to the experimental results. The proposed checker is expected to be useful for RBC evaluation in medical practices.
منابع مشابه
Group B Streptococcus impairs erythrocyte deformability in neonates more than in adults.
Group B beta-haemolytic Streptococcus (GBS) may cause severe septic shock and death in neonates, whereas this is rarely the case in adults. As impaired red blood cell (RBC) deformability might disturb microcirculation in septic shock, the in vitro effects of GBS (1.7 x 10(8) cfu/ml) on RBC deformation (rheoscope) and haemolysis were studied in blood from preterm infants, term neonates, and adul...
متن کاملStreptococcus impairs erythrocyte deformability in neonates more than in adults
Accepted 6 November 1995 Abstract Group B ,-haemolytic Streptococcus (GBS) may cause severe septic shock and death in neonates, whereas this is rarely the case in adults. As impaired red blood cell (RBC) deformability might disturb microcirculation in septic shock, the in vitro effects of GBS (1-7X108 cfu/ml) on RBC deformation (rheoscope) and haemolysis were studied in blood from preterm infan...
متن کاملMeasurement Techniques for Red Blood Cell Deformability: Recent Advances
Human red blood cells (RBCs) or erythrocytes have remarkable deformability. Upon external forces, RBCs undergo large mechanical deformation without rupture, and they restore to original shapes when released. The deformability of RBCs plays crucially important roles in the main function of RBCs oxygen transport through blood circulation. RBCs must withstand large deformations during repeated pas...
متن کاملHuman red blood cell behavior under homogeneous extensional flow in a hyperbolic-shaped microchannel.
It is well known that certain pathological conditions result in a decrease of red blood cells (RBCs) deformability and subsequently can significantly alter the blood flow in microcirculation, which may block capillaries and cause ischemia in the tissues. Microfluidic systems able to obtain reliable quantitative measurements of RBC deformability hold the key to understand and diagnose RBC relate...
متن کاملDeformability and intrinsic material properties of neonatal red blood cells.
Whole cell and membrane deformability are essential for red blood cell (RBC) survival and for effective blood flow. Neonatal RBCs display several specific properties (eg, large size, high hemoglobin F) that could influence their deformation characteristics and contribute to their shortened life span. The present study was designed to compare selected rheologic properties (cellular deformability...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Micromachines
دوره 7 شماره
صفحات -
تاریخ انتشار 2016