Field performance of the Chemcatcher passive sampler for monitoring hydrophobic organic pollutants in surface water.
نویسندگان
چکیده
Six field trials were carried out to assess the performance of the Chemcatcher passive sampler alongside spot sampling for monitoring priority hydrophobic organic pollutants (polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides) in a wide range of conditions in surface water. The trials were performed in three European rivers: Elbe (Czech Republic), Alna (Norway) and Meuse (Netherlands), in two seasons (April-June 2004, and September-October 2004). Samplers spiked with performance reference compounds (PRCs) were deployed for either 14 or 28 days. Ten spot samples of water were collected over the course of the trial and filtered through a 0.7 microm glass fibre filter. Concentrations of pollutants measured using the Chemcatcher were compared with the average concentrations found in spot samples. This study describes the operational performance of Chemcatcher for measuring hydrophobic (log K(OW) 3.7-6.8) chemicals in surface water. Site specific Chemcatcher sampling rates up to 0.5 L d(-1) were found using the PRC approach that reduced the uncertainty in estimates of sampling kinetics where temperature, local flow conditions and biofouling potential varied between sites and seasons, and with time during sampler exposure. The limits of quantification of sampled analytes ranged from one to tens ng L(-1). Highest sensitivity was achieved for compounds with a favourable combination of low instrument quantification limits and high sampling rates including dieldrin, hexachlorobenzene, lindane, pentachlorobenzene, and PAHs with less than five aromatic rings. The direct comparison of time weighted average (TWA) concentrations (mostly close to method limits of detection) obtained using passive and spot sampling was possible for lindane, hexachlorobenzene, and PAHs < 4 rings. Implications of using the Chemcatcher in regulatory monitoring programmes such as the European Union Water Framework Directive are discussed.
منابع مشابه
Calibration and field performance of triolein embedded acetate membranes for passive sampling persistent organic pollutants in water.
Triolein embedded cellulose acetate membrane (TECAM) passive samplers provide potentially powerful tool for monitoring time weighted average concentrations (C(TWA)) of trace hydrophobic organic contaminants in water. To study the field performance of TECAM, exchange kinetics of chemicals between water and TECAM were studied at different temperature and water flow rates. Results showed that the ...
متن کاملEffect of the orientation and fluid flow on the accumulation of organotin compounds to Chemcatcher passive samplers.
Monitoring of harmful substances in an aquatic environment is based on spot sampling which is the only sampling technique accepted by environmental authorities in the European Union. Still the implementation of the European Union Water Framework Directive (WFD) requires novel sampling tools for monitoring priority pollutants since their concentrations in natural waters can often remain below th...
متن کاملCalibration and field evaluation of the Chemcatcher® passive sampler for monitoring metaldehyde in surface water.
Metaldehyde is a potent molluscicide. It is the active ingredient in most slug pellets used for crop protection. This polar compound is considered an emerging pollutant. Due to its environmental mobility, metaldehyde is frequently detected at impacted riverine sites, often at concentrations above the EU Drinking Water Directive limit of 0.1µgL-1 for an individual pesticide. This presents a prob...
متن کاملPassive sampling of perfluorinated chemicals in water: in-situ calibration.
Perfluorinated chemicals (PFCs) have been recognised as environmental pollutants that require monitoring. A modified polar organic chemical integrative sampler (POCIS) is able to quantify aqueous PFCs. However, with varying external water velocity, PFC sampling rates (Rs) may change, affecting accuracy of derived water concentrations. To facilitate field deployment of this sampler, two methods ...
متن کاملShort-term exposure testing of six different passive samplers for the monitoring of hydrophobic contaminants in water.
Passive sampling devices are increasingly relied upon for monitoring non-polar organic contaminants in water. While many types of devices are available they have seldom been evaluated alongside each other. We tested six passive sampling devices namely: Chemcatcher, two modified versions of the membrane enclosed sorptive coating (MESCO I (m) and MESCO II), silicone rod and strip and semipermeabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of environmental monitoring : JEM
دوره 12 4 شماره
صفحات -
تاریخ انتشار 2010