Comparison of cuff-pressure changes in silicone and PVC laryngeal masks during nitrous oxide anaesthesia in spontaneously breathing children.
نویسندگان
چکیده
BACKGROUND The purpose of this study was to evaluate the cuff pressures of four different laryngeal masks in paediatric patients undergoing routine surgery and to determine whether there is a substantial increase in cuff pressure when silicone masks are used compared to PVC laryngeal mask airways. METHODS Hundred and forty patients aged < 16 yr were randomly allocated to receive one of four extra glottic airway devices: LMA-Classic; LMA-Unique; Soft Seal; or Cobra-PLA. Intracuff pressure was monitored continuously throughout the operative intervention. The primary outcome was measurement of an increase in cuff pressure. First attempt success rate, effective airway time, anatomical position of the airway and incidence of airway morbidity data were monitored. RESULTS Mean cuff pressure increased within 5 min of N2O exposure, and was substantially higher in the silicone LMA-C,compared to the PVC-based extra glottic airway devices tested, reaching a plateau of the cuff pressure after 45 min.The overall first attempt success rate (97%) and the mean effective airway time (24 ± 9 sec) were very satisfactory and all patients underwent successful surgery. Anatomical position was adequate in most airways, although in 34%of the patients in the Cobra group herniation of either the epiglottis or arytenoids were detected. Airway morbidity due to the devices was insignificant. CONCLUSIONS This study demonstrated a substantial increase in cuff pressure during anaesthesia for children in whom a silicone-based LMA-C was used, whereas PVC-based extra glottic airway devices showed a much lower increase.
منابع مشابه
Abdominal pressure during laparoscopy: effects of fentanyl.
BACKGROUND In patients breathing spontaneously during anaesthesia, expiration is active and opioids enhance this effect. The mechanical consequences are not well characterized. METHODS We studied 14 patients undergoing laparoscopy for minor gynaecological procedures, anaesthetized with isoflurane in nitrous oxide, and breathing spontaneously through a laryngeal mask airway. We made direct rec...
متن کاملTracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need
BACKGROUND To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. METHOD In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and la...
متن کاملLaryngeal mask airway performance: effect of cuff deflation during anaesthesia.
We studied the effect of deflating the laryngeal mask airway (LMA) cuff in situ on recorded respiratory tidal ventilation in 30 spontaneously breathing anaesthetized patients. Another 26 patients were studied in whom the LMA cuff was undisturbed. Deflation of the cuff to a pressure of 22 mm Hg (below an estimated arteriolar perfusion pressure of the pharyngeal mucosa), by removing approximately...
متن کاملThe effect of nitrous oxide on laryngeal mask cuff pressure.
During general anesthesia with the laryngeal mask airway (LMA), a significant increase in cuff pressure due to diffusion of nitrous oxide through the cuff wall occurs. This descriptive clinical study was conducted in a university teaching hospital ambulatory surgical center with 100 patients (ASA physical status, I-III; age, 5 months to 76 years; weight, 5.8-146.3 kg) undergoing general anesthe...
متن کاملEvaluation of pressure changes in a new design tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia.
We have measured pressure changes in a newly designed tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia compared with a Mallinckrodt Lo-Contour tube and a Portex Profile tube. The pressure increases in both control groups were significantly greater than those with the new design (P < 0.0001 in each case). The mean increase in pressure in the Mallinckrodt Lo-Contour tube...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anaesthesiology intensive therapy
دوره 44 2 شماره
صفحات -
تاریخ انتشار 2012