Evaluation of geometric sensitivity for hybrid PET.
نویسندگان
چکیده
UNLABELLED Hybrid PET systems have spatially varying sensitivity profiles. These profiles are dependent on imaging parameters, namely, number of heads, head configuration, spacing between gantry stops, radius of rotation (RoR), and coincident head acceptance angle. METHODS Sensitivity profiles were calculated across a 500-mm field of view (FoV) for a representative set of existing and theoretic 2-, 3-, and 4-head hybrid PET systems. The head configuration was defined by alpha(n), which describes the angular separation between head 1 and head n. Simulated configurations were 2 head ([alpha(2)] = [180 degrees ]), 3 head ([alpha(2), alpha(3)] = [120 degrees, 240 degrees ] and [90 degrees, 180 degrees ]), and 4 head ([alpha(2), alpha(3), alpha(4)] = [90 degrees, 180 degrees, 270 degrees ]). Four transverse acceptance angles, measured from the perpendicular of the crystal to the surface, were simulated: 90 degrees, 45 degrees, 23 degrees, and 11 degrees. Two RoRs were considered: 250 and 300 mm. Each head was rotated through 360 degrees in 128 steps, and no physical collimation was modeled. RESULTS For a 250-mm RoR and 90 degrees acceptance angle, the sensitivities relative to [alpha(2)] = [180 degrees ] were [alpha(2), alpha(3)] = [120 degrees, 240 degrees ], 183%; [alpha(2), alpha(3)] = [90 degrees, 180 degrees ], 159%; and [alpha(2), alpha(3), alpha(4)] = [90 degrees, 180 degrees, 270 degrees ], 317%. Increasing RoR to 300 mm decreased [alpha(2)] = [180 degrees ] sensitivity by approximately 12%; all other configurations were decreased by approximately 75% of their 250-mm RoR sensitivities. Decreasing the acceptance angle to 45 degrees decreased sensitivities to [alpha(2), alpha(3)] = [120 degrees, 240 degrees ], 100%; [alpha(2), alpha(3)] = [90 degrees, 180 degrees ], 105%; and [alpha(2), alpha(3), alpha(4)] = [90 degrees, 180 degrees, 270 degrees ], 210%. The 2-head [alpha(2)] = [180 degrees ] system sensitivity was not affected. The configuration was the most important factor affecting the shape of the sensitivity profiles. For a 250-mm RoR and 90 degrees acceptance angle, [alpha(2)] = [180 degrees ] concentrated sensitivity in the FoV center, [alpha(2), alpha(3)] = [120 degrees, 240 degrees ] had a slightly increased peripheral sensitivity, and the profiles for both [alpha(2), alpha(3)] = [90 degrees, 180 degrees ] and [alpha(2), alpha(3), alpha(4)] = [90 degrees, 180 degrees, 270 degrees ] were completely flat. CONCLUSION Sensitivity profiles are affected strongly by imaging parameters; however, profiles can be shaped to concentrate on an annulus or distribute sensitivity uniformly over the FoV. Also, the 4-head system showed a markedly higher sensitivity than either of the 3-head systems.
منابع مشابه
Recent Advances in PET-MR Hybrid contrast agent
Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...
متن کاملFDG-PET/MRI fused data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment
Background: To retrospectively describe imaging characteristics of liver metastases on fused FDG-PET/ MRI data sets and to compare the diagnostic accuracy of MRI and fused FDG-PET/MRI data sets for the detection of liver metastases in patients undergoing systemic anticancer treatment. Materials and Methods: 43 oncological patients (mean age: 56+/- 11 years) were investigated by FDG-PET...
متن کاملDesign and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling
Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...
متن کاملValidation and evaluation of a GATE model for MAMMI PET scanner
Introduction:MAMMI is a dedicated PET based on high resolution detectors placed close to the breast. In this study, we presented a GATE model for the simulation of MAMMI scanner and model its performance of the MAMMI based on an adaptation of the NU 4-2008 NEMA standard. Methods:A detailed of geometry MAMMI system that uses scintillation crystals coupled...
متن کاملEvaluation of [18F]-FDG-Based Hybrid Imaging Combinations for Assessment of Bone Marrow Involvement in Lymphoma at Initial Staging
The purpose of our study was to determine the value of different hybrid imaging combinations for the detection of focal and diffuse bone marrow infiltration in lymphoma. Patients with histologically proven lymphoma, who underwent both [18F]-FDG-PET/CT and whole-body MRI (including T1- and diffusion-weighted [DWI] sequences) within seven days, and a subsequent bone marrow biopsy, were retrospect...
متن کاملDetection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey
Objective(s): The aim of this study was to analyze detection rates and effectiveness of 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 42 7 شماره
صفحات -
تاریخ انتشار 2001