Clinical implications of internal carotid artery flow impairment caused by filter occlusion during carotid artery stenting.

نویسندگان

  • O-K Kwon
  • S H Kim
  • E A Jacobsen
  • M P Marks
چکیده

BACKGROUND AND PURPOSE Membrane filters are EPDs, which preserve ICA flow during CAS. However, ICA flow arrest may occur with filter use. This report describes the angiographic, clinical, and histopathologic features of the filter occlusion. MATERIALS AND METHODS Sixty-one consecutive patients with cervical carotid stenosis treated by CAS by using a single type of filter device were evaluated. All patients were on dual antiplatelet treatment and fully heparinized. Prestent dilation was performed in all patients. Poststent dilation was performed in 15 patients. Control angiograms were obtained and evaluated after each step of the CAS procedure. All filters were inspected for debris, and if present, histology was obtained. RESULTS CAS was successfully performed in all cases with <20% residual stenosis. Filter occlusion occurred in 6 patients (9.8%). It developed immediately after stent deployment in 4, and after a second prestent dilation in 2. Five of the 6 had severe carotid stenosis. In all patients, filter withdrawal led to immediate and complete restoration of ICA flow. In 1 patient, acute embolic M1 occlusion occurred immediately after filter withdrawal but was successfully treated with thrombolysis. None of filter-occlusion group had permanent neurologic deficits. Gross and microscopic examinations demonstrated that the pores of the filters were occluded mainly by fibrin. Postoperative diffusion MR imaging revealed no difference between filter-occlusion and non-filter-occlusion groups. CONCLUSIONS ICA flow arrest due to filter occlusion during CAS is relatively common and occurs more frequently in severe stenosis. It resolves rapidly after filter removal and does not appear to worsen outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Carotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion

Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...

متن کامل

A Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform

Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...

متن کامل

Carotid Artery Stenting for Symptomatic Stenosis of the Cervical Carotid Artery Associated with Persistent Primitive Hypoglossal Artery: A Case Report

Objective: A case of symptomatic cervical carotid artery stenosis with persistent primitive hypoglossal artery (PPHA) treated by carotid artery stenting (CAS) with appropriate embolic protection is reported. Case Presentation: The patient was a 65-year-old male presenting with left hemiplegia. MRI revealed infarction in the right cerebral hemisphere, and cerebral angiography demonstrated stenos...

متن کامل

Comparison of Flow Impairment during Carotid Artery Stenting Using Two Types of Eccentric Filter Embolic Protection Devices

We investigated the angiographic findings and the clinical outcomes after carotid artery stenting (CAS) using two different, eccentric filter embolic protection devices (EPDs). Between July 2010 and August 2015, 175 CAS procedures were performed using a self-expandable closed-cell stent and a simple eccentric filter EPD (FilterWire EZ in 86 and Spider FX in 89 procedures). The angiographic find...

متن کامل

Successful Carotid Stenting for Chronic Total Occlusion of the Internal Carotid Artery

A 64-year-old man complaining of pulsatile headache was admitted. Imaging studies revealed a near-total occlusion of the right proximal internal carotid artery (ICA) with slow antegrade flow into the distal ICA. Right cerebral flow was supplied by collateral flow through the posterior communicating and ophthalmic arteries. He was successfully treated by carotid artery stenting. No new neurologi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2012