Controller design for wind turbine load reduction via multi- objective parameter synthesis
نویسندگان
چکیده
During the design process for a wind turbine load reduction controller many different, sometimes conflicting requirements must be fulfilled simultaneously. If the requirements can be expressed as mathematical criteria, such a design problem can be solved by a criterion-vector and multi-objective design optimization. The software environment MOPS (Multi-Objective Parameter Synthesis) supports the engineer for such a design optimization. In this paper MOPS is applied to design a multi-objective load reduction controller for the well-known DTU 10 MW reference wind turbine. A significant reduction in the fatigue criteria especially the blade damage can be reached by the use of an additional Individual Pitch Controller (IPC) and an additional tower damper. This reduction is reached as a trade-off with an increase of actuator load.
منابع مشابه
Improvement of Frequency Fluctuations in Microgrids Using an Optimized Fuzzy P-PID Controller by Modified Multi Objective Gravitational Search Algorithm
Microgrids is an new opportunity to reduce the total costs of power generation and supply the energy demands through small-scale power plants such as wind sources, photo voltaic panels, battery banks, fuel cells, etc. Like any power system in micro grid (MG), an unexpected faults or load shifting leads to frequency oscillations. Hence, this paper employs an adaptive fuzzy P-PID controller for f...
متن کاملFixed-structure H∞ control design for linear Individual Pitch Control of two-bladed wind turbines
In this paper, a fixed-structure Individual Pitch Control (IPC) design method for two-bladed wind turbines is presented. IPC is an active load reduction technique designed to lower wind turbine loads, which are caused by continuously varying wind conditions. Based on load measurements, the once-per-revolution (1P) loads and harmonics of this frequency (2P, 3P, etc.) can be reduced by rotating (...
متن کاملNonlinear Dynamic Inversion Control for Wind Turbine Load Mitigation based on Wind Speed Measurement
The design of an advanced controller for wind turbine load mitigation is presented. The controller is based on Nonlinear Dynamic Inversion control methods combined with Pseudo Control Hedging to account for the actuator limits and a two degree of freedom control system for the collective pitch control of the rotor blades. The controller uses wind speed measurement information to adjust to wind ...
متن کاملBlade Load Control of Wind Turbine Based on Variable-pitch Control Strategies
The control strategies of blade loads are proposed for the characteristics of blade stresses of variable-speed variablepitch wind turbine. Blade loads are divided into two static and dynamic components. The pitch angle and generator torque are controlled by Single neuron PID controller in the static part. Variables are converted from rotational coordinate to fixed coordinate through multi-blade...
متن کاملModeling and Neuro-fuzzy Controller Design of a Wind Turbine in Full-load Region Based on Operational Data
In this paper, dynamic modeling of a Vestas 660 kW wind turbine and its validation are performed based on operational data extracted from Eoun-Ebn-Ali wind farm in Tabriz, Iran. The operational data show that the turbine under study, with a classical PI controller, encounters high fluctuations when controlling the output power at its rated value. The turbine modeling is performed by deriving th...
متن کامل