Integral radiation dose to normal structures with conformal external beam radiation.

نویسندگان

  • Hidefumi Aoyama
  • David Clark Westerly
  • Thomas Rockwell Mackie
  • Gustavo H Olivera
  • Søren M Bentzen
  • Rakesh R Patel
  • Hazim Jaradat
  • Wolfgang A Tome
  • Mark A Ritter
  • Minesh P Mehta
چکیده

BACKGROUND This study was designed to evaluate the integral dose (ID) received by normal tissue from intensity-modulated radiotherapy (IMRT) for prostate cancer. METHODS AND MATERIALS Twenty-five radiation treatment plans including IMRT using a conventional linac with both 6 MV (6MV-IMRT) and 20 MV (20MV-IMRT), as well as three-dimensional conformal radiotherapy (3DCRT) using 6 MV (6MV-3DCRT) and 20 MV (20MV-3DCRT) and IMRT using tomotherapy (6MV) (Tomo-IMRT), were created for 5 patients with localized prostate cancer. The ID (mean dose x tissue volume) received by normal tissue (NTID) was calculated from dose-volume histograms. RESULTS The 6MV-IMRT resulted in 5.0% lower NTID than 6MV-3DCRT; 20 MV beam plans resulted in 7.7%-11.2% lower NTID than 6MV-3DCRT. Tomo-IMRT NTID was comparable to 6MV-IMRT. Compared with 6MV-3DCRT, 6MV-IMRT reduced IDs to the rectal wall and penile bulb by 6.1% and 2.7%, respectively. Tomo-IMRT further reduced these IDs by 11.9% and 16.5%, respectively. The 20 MV did not reduce IDs to those structures. CONCLUSIONS The difference in NTID between 3DCRT and IMRT is small. The 20 MV plans somewhat reduced NTID compared with 6 MV plans. The advantage of tomotherapy over conventional IMRT and 3DCRT for localized prostate cancer was demonstrated in regard to dose sparing of rectal wall and penile bulb while slightly decreasing NTID as compared with 6MV-3DCRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT

Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans.   Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...

متن کامل

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

متن کامل

Comparison of conventional and 3D conformal treatments using linac energies for prostate cancer

Background: To evaluate the dosimetric difference between conventional and three-dimensional conformal Radiotherapy (3D-CRT) using 6 and 18 MV X-ray photons. Materials and Methods: Computed tomography scans of 26 pelvic patients were acquired and transferred to the 3D treatment planning system. For each patient, 8 Conventional plans (3, 4, 5 and 6 Fields) and one 3D-CRT plan were prep...

متن کامل

The efficacy of conventional external beam, three-dimensional conformal, intensity-modulated, particle beam radiation, and brachytherapy for localized prostate cancer.

Technologic advances in radiation treatment planning and delivery have generated popular interest in the different radiation therapy techniques used in treating patients with localized prostate cancer. Throughout the past decade, high-energy (> 4 MV) linear accelerators have largely replaced Cobalt machines in external beam radiation therapy (EBRT) delivery. Conventional EBRT has been used to t...

متن کامل

AbstractID: 1109 Title: Integral Dose in External Beam Photon Radiotherapy

ID: 1109 Title: Integral Dose in External Beam Photon Radiotherapy Integral dose is the volume integral of the dose deposited in the patient and is equal to the mean dose times the volume. The integral dose is also the area under the curve of a differential dose absolute-volume histogram. It is widely believed that IMRT increases the integral dose to normal tissues as compared to conventional r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 64 3  شماره 

صفحات  -

تاریخ انتشار 2006