A fluorescent responsive hybrid nanogel for closed-loop control of glucose.

نویسندگان

  • Weitai Wu
  • Shoumin Chen
  • Yumei Hu
  • Shuiqin Zhou
چکیده

BACKGROUND The concept of closed-loop control of glucose, in which continuous glucose sensing is coupled to a fully automated insulin delivery device, without human input, has been an attractive idea for diabetes management. This study presents a new class of hybrid nanogels that can integrate glucose sensing and glucose-responsive insulin release into a single nano-object. METHODS Zinc oxide@poly[N-isopropylacrylamide (NIPAM)-acrylamide (AAm)- 2-aminomethyl-5-fluorophenylboronic acid (FPBA)] hybrid nanogels were synthesized and investigated for size, morphology, volume phase transition, photoluminescence properties, and in vitro insulin release under different glucose concentrations. Glucose sensing was performed both in phosphate-buffered saline (PBS) and in blood samples. The insulin release in PBS of varying glucose levels, as well as a stepwise treatment between two glucose levels (126.0 and 270.0 mg/dl), was performed to test the glucose-responsive insulin release ability of the hybrid nanogels. RESULTS Zinc oxide@poly(NIPAM-AAm-FPBA) hybrid nanogels can sensitively and selectively detect glucose in highly reproducible fluorescent signals over the clinically relevant glucose concentration range of 18-540 mg/dl. The glucose-responsive volume phase transition of the nanogels can further regulate the release of the preloaded insulin. The insulin release from the nanogels exhibits the slowest rate (~5% released in 76 h) at a normal glucose level (108.0 mg/dl) but becomes quicker and quicker as the glucose increases to higher and higher levels. CONCLUSIONS The rationally designed hybrid nanogel can optically signal the glucose level with high sensitivity and selectivity and simultaneously regulate the insulin release rate in response to the glucose reading, which shows a promising concept toward the development of a miniaturized closed-loop glycemic control system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Responsive polymer-fluorescent carbon nanoparticle hybrid nanogels for optical temperature sensing, near-infrared light-responsive drug release, and tumor cell imaging.

Fluorescent carbon nanoparticles (FCNPs) have been successfully immobilized into poly(N-isopropylacrylamide-co-acrylamide) [poly(NIPAM-AAm)] nanogels based on one-pot precipitation copolymerization of NIPAM monomers with hydrogen bonded FCNP-AAm complex monomers in water. The resultant poly(NIPAM-AAm)-FCNP hybrid nanogels can combine functions from each building block for fluorescent temperatur...

متن کامل

A hybrid solution approach for a multi-objective closed-loop logistics network under uncertainty

The design of closed-loop logistics (forward and reverse logistics) has attracted growing attention with the stringent pressures of customer expectations, environmental concerns and economic factors. This paper considers a multi-product, multi-period and multi-objective closed-loop logistics network model with regard to facility expansion as a facility location–allocation problem, which more cl...

متن کامل

An Optimization Model for Multi-objective Closed-loop Supply Chain Network under uncertainty: A Hybrid Fuzzy-stochastic Programming Method

In this research, we address the application of uncertaintyprogramming to design a multi-site, multi-product, multi-period,closed-loop supply chain (CLSC) network. In order to make theresults of this article more realistic, a CLSC for a case study inthe iron and steel industry has been explored. The presentedsupply chain covers three objective functions: maximization ofprofit, minimization of n...

متن کامل

Dynamic Load Carrying Capacity of Mobile-Base Flexible-Link Manipulators: Feedback Linearization Control Approach

This paper focuses on the effects of closed- control on the calculation of the dynamic load carrying capacity (DLCC) for mobile-base flexible-link manipulators. In previously proposed methods in the literature of DLCC calculation in flexible robots, an open-loop control scheme is assumed, whereas in reality, robot control is achieved via closed loop approaches which could render the calculated ...

متن کامل

Robust Adaptive Neural Control of the Blood Glucose for Type 1 Diabetic Patients in Presence of Meals

In this paper, the blood glucose control for type 1 diabetic patients in the presence of model uncertainties and uncertain meals is considered. In order to present an efficient control approach, it is assumed that the dynamics describe the mechanism of the blood glucose regulation in type 1 diabetic patients are completely unknown. Hence, based on the universal approximation property of the rad...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 2012