Comparison of bond strength of a pressed ceramic fused to metal versus feldspathic porcelain fused to metal.

نویسندگان

  • Daniel M Schweitzer
  • Gary R Goldstein
  • John L Ricci
  • N R F A Silva
  • Eugene L Hittelman
چکیده

PURPOSE To compare the debonding/crack initiation strength (D/CIS) of a low-fusing pressable leucite-based glass ceramic (PC) fused to metal to a feldspathic porcelain (FP) fused to metal. MATERIALS & METHODS As per ISO 9693:1999, 40 rectangular metal specimens (25.0 mm x 0.5 mm x 3.0 mm) were prepared. Twenty of the specimens were cast in a base metal nickel-chromium alloy (BA), and 20 were cast in a noble metal palladium-silver alloy (NA). Ten randomly selected NA and BA alloy specimens had FP applied. The remaining 10 NA and BA alloy specimens had ash-free wax patterns applied, the metal-wax complexes invested, and were pressed with a PC. The dimensions of the ceramic specimens were 8.0 mm x 1.0 mm x 3.0 mm, creating a combined metal-ceramic complex thickness of 1.5 mm. All specimens were subject to a three-point bending test at a crosshead speed of 1.5 mm/min. Fracture loads were recorded in Newtons and D/CISs calculated by the formula tau(b)=k x F(fail). RESULTS Mean D/CISs, measured in MPa (standard deviations): NA-FP 32.56 (4.62), NA-PC 30.23 (5.06), BA-FP 30.98 (4.41), and BA-PC 31.81 (3.48). A two-way ANOVA (p > 0.05) did not demonstrate significant difference between groups. CONCLUSION The debonding/crack initiation strength of a low-fusing pressable leucite-based glass ceramic fused to metal was equivalent to that of a feldspathic porcelain fused to metal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Effect of Nd:YAG Laser and Sandblasting on Shear Bond Strength of a Commercial Ni-Cr Alloy to Porcelain

Introduction: Failures might occur at metal‒porcelain interfaces as a problem with metal‒ceramic restorations even with the application of airborne-particle abrasion technique. This study was undertaken to evaluate the effect of Nd:YAG laser treatment on the bond strength of porcelain fused to metal. Methods:  Twenty-four cylindrical specimens (4 mm in diameter and 4 mm in height) were made of ...

متن کامل

Metal-ceramic bond strength between a feldspathic porcelain and a Co-Cr alloy fabricated with Direct Metal Laser Sintering technique

PURPOSE The aim of the present study was to record the metal-ceramic bond strength of a feldspathic dental porcelain and a Co-Cr alloy, using the Direct Metal Laser Sintering technique (DMLS) for the fabrication of metal substrates. MATERIALS AND METHODS Ten metal substrates were fabricated with powder of a dental Co-Cr alloy using DMLS technique (test group) in dimensions according to ISO 96...

متن کامل

Effect of Opaque Porcelain Thickness Bond Strength of Porcelain to Ni-Cr Alloys

Objectives: Metal-ceramic restorations are the standard by which all esthetic restorations are measured. Fracture of dental restorations is a multifactorial problem, which is serious and costly. Debonding of porcelain from metal substructure and the bond strength depend on many factors. The purpose of this study was to determine whether or not the opaque porcelain thickness has a significant ef...

متن کامل

Shear bond strength of a hot pressed Au-Pd-Pt alloy-porcelain dental composite.

OBJECTIVES The purpose of this study was to evaluate the effect of hot pressing on the shear bond strength of a Au-Pt-Pd alloy-porcelain composite. METHODS Several metal-porcelain composites specimens were produced by two different routes: conventional porcelain fused to metal (PFM) and hot pressing. In the latter case, porcelain was hot pressed onto a polished surface (PPPS) as well as a rou...

متن کامل

A comparative study on the bond strength of porcelain to the millingable Pd-Ag alloy

PURPOSE The porcelain fused to gold has been widely used as a restoration both with the natural esthetics of the porcelain and durability and marginal fit of metal casting. However, recently, due to the continuous rise in the price of gold, an interest towards materials to replace gold alloy is getting higher. This study compared the bond strength of porcelain to millingable palladium-silver (P...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of prosthodontics : official journal of the American College of Prosthodontists

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2005