"Tripolar" hip arthroplasty for failed hip resurfacing: nineteen years follow-up.
نویسندگان
چکیده
The authors describe the case of a 37-year-old patient who sustained a subcapital femoral neck fracture six months after ICLH double-cup hip resurfacing. As the polyethylene acetabular resurfacing component was undamaged and well fixed, a standard femoral stem with a bipolar head was inserted. The outer diameter of the bipolar head was chosen to fit the resurfacing socket. The "tripolar" hip arthroplasty has functioned well for 19 years and was revised for aseptic cup loosening. The cemented femoral stem was still well fixed and was not revised. Although the "tripolar" hip has functioned well in our case, we believe it is not indicated for metal on metal bearings. In this case the use of an appropriate modular head with a correct head-socket clearance is preferred.
منابع مشابه
Total Hip Arthroplasty with Modular Stem for Dysplastic Hips in South Asian Population
Introduction: Optimum component positioning and orientation is required to optimize the functional result during total hip arthroplasty for dysplastic hips. Patients and methods: Sixty-two patients (66 hips) including 33 males and 29 females underwent total hip arthroplasty using modular stem prosthesis at an average age of 40.6 years (range 17 to 49 years). Nineteen hips were clas...
متن کاملMid-Term Results of Metal-on-Metal Hip Resurfacing for Treatment of Osteoarthritis Secondary to Developmental Dysplasia of the Hip: A Minimum of 8-Years of Follow-Up
BACKGROUND Metal-on-metal resurfacing arthroplasty is an attractive alternative to conventional total hip arthroplasty in patients with osteoarthritis secondary to developmental dysplasia of the hip (DDH). The purpose of this study was to assess the mid-term clinical outcome and mid-term survivorship of Metal-on-metal resurfacing arthroplasty in patients suffering from osteoarthritis secondary ...
متن کاملRevision of failed hip resurfacing to total hip arthroplasty rapidly relieves pain and improves function in the early post operative period
We reviewed the results of 25 consecutive patients who underwent revision of a hip resurfacing prosthesis to a total hip replacement. Revisions were performed for recurrent pain and effusion, infection and proximal femoral fractures. Both components were revised in 20 cases.There were 12 male and 13 female patients with average time to revision of 34.4 and 26.4 months respectively. The mean fol...
متن کاملProspective Study Comparing Functional Outcomes and Revision Rates Between Hip Resurfacing and Total Hip Arthroplasty: Preliminary Results for 2 Years
There is a need of independent prospective studies about modern generation of hip resurfacing implants. The aim of this propective observational study was to compare the functional outcomes and revision rates with hip resurfacing arthroplasty and total hip arthroplasty and to present the preliminary results at 2 years. Patients included were recruited prospectively in the Partial Pelvic Replace...
متن کاملComparison of hip function and quality of life of total hip arthroplasty and resurfacing arthroplasty in the treatment of young patients with arthritis of the hip joint at 5 years
OBJECTIVE To compare the medium-term clinical effectiveness of total hip arthroplasty and resurfacing arthroplasty. DESIGN Single centre, two-arm, parallel group, assessor blinded, randomised controlled trial with 1:1 treatment allocation. SETTING A large teaching hospital in England. PARTICIPANTS 122 patients older than 18 years with severe arthritis of the hip joint, suitable for resurf...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Belgica
دوره 67 4 شماره
صفحات -
تاریخ انتشار 2001