Moisture content determination by DXA Improved method based on dual-energy X-ray absorptiometry (DXA) for nondestructive evaluation of solid wood moisture content

نویسنده

  • Takashi Tanaka
چکیده

An accurate, rapid, and convenient method is presented for moisture content (MC) 10 determination of solid wood based on dual-energy X-ray absorptiometry (DXA). Poly(methyl methacrylate)-equivalent thicknesses (PMMA-EThs) of sugi (Cryptomeria japonica D. Don) wood blocks and pure water were measured by means of a wide range of X-ray tube voltages (20–100 kV). The ratio of the PMMA-ETh of pure water to that of wood decreased as X-ray tube voltage was increased, suggesting that an appropriate pair of tube voltages for DXA is 20 15 kV and 100 kV. According to this result, X-ray images of thirty wood samples were taken at 20 kV and 100 kV tube voltages, and their average PMMA-Eths from both images was determined. There was a strong negative correlation between the wet-basis MC of the wood sample and the ratio of its PMMA-Eth at 100 kV to that at 20 kV. A regression equation was developed for estimating the dry-basis MC of wood samples from their PMMA-ETh ratios. 20 The standard error of estimate was 2.2%, which is better than those determined for electric moisture meters. This approach may lead to the development of a practical, nondestructive moisture meter for wood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Singh index accuracy and dual energy X-ray absorptiometry bone mineral density measurement for evaluating osteoporosis

Background: The Singh index is an inexpensive simple method to evaluate bone density, commonly used to assess osteoporosis is based on the radiological appearance of the trabecular bone structure of the proximal femur on a plain antero-posterior (AP) radiograph. The purpose of this study was to compare between Singh index and bone mineral density measurement using dual energy X-ray abs...

متن کامل

Evaluation of dual-energy X-ray absorptiometry for body-composition assessment in piglets and term human neonates.

The reproducibility, accuracy, and precision of dual-energy X-ray absorptiometry (DXA) was assessed by scanning 13 piglets (1471-5507 g) in triplicate. In four piglets, fat content was increased with porcine lard around the abdomen; additional measurements were performed on these animals. Reproducibility in DXA measurements from the animals without added fat was 0.09% for body weight, 1.95% for...

متن کامل

Invited Review Use of dual-energy x-ray absorptiometry in non-ruminant nutrition research

Precise body composition measurements are essential in animal nutrition studies because the impact of treatments is evaluated based on changes in body weight and composition. Various indirect techniques for animal compositional evaluation have been developed and evaluated for applicability in animal nutrition studies. A fast, accurate, minimally invasive method that requires little input is con...

متن کامل

Validation of fan beam dual energy x ray absorptiometry for body composition assessment in adults aged 18-45 years.

BACKGROUND Pencil beam dual energy x ray absorptiometry (DXA) has been shown to provide valid estimates of body fat (%BF), but DXA fan beam technology has not been adequately tested to determine its validity. OBJECTIVE To compare %BF estimated from fan beam DXA with %BF determined using two and three compartment (2C, 3C) models. METHODS Men (n = 25) and women (n = 31), aged 18-41 years, par...

متن کامل

Dual-energy X-ray absorptiometry (DXA) can accurately and nondestructively measure the body composition of small, free-living rodents.

Dual-energy x-ray absorptiometry (DXA) is a nondestructive technique that can potentially measure specific components of whole-body composition in free-living and lab-raised animals. Our aim was to test the ability of DXA to measure the composition of a common arvicoline rodent, the northern red-backed vole (Clethrionomys rutilus). We used a DXA apparatus to obtain measurements of fat mass (FM)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017