Microwave-induced thermoacoustic tomography using multi-sector scanning.
نویسندگان
چکیده
A study of microwave-induced thermoacoustic tomography of inhomogeneous tissues using multi-sector scanning is presented. A short-pulsed microwave beam is used to irradiate the tissue samples. The microwave absorption excites time-resolved acoustic waves by thermoelastic expansion. The amplitudes of the acoustic waves are strongly related to locally absorbed microwave-energy density. The acoustic waves may propagate in all spatial directions. A focused ultrasonic transducer is employed to acquire temporal acoustic signals from multiple directions. Each detected signal is converted into a one-dimensional (1D) image along the acoustic axis of the transducer. The cross-sectional images of the tissue samples are calculated by combining all of the 1D images acquired in the same planes.
منابع مشابه
Scanning thermoacoustic tomography in biological tissue.
Microwave-induced thermoacoustic tomography was explored to image biological tissue. Short microwave pulses irradiated tissue to generate acoustic waves by thermoelastic expansion. The microwave-induced thermoacoustic waves were detected with a focused ultrasonic transducer. Each time-domain signal from the ultrasonic transducer represented a one-dimensional image along the acoustic axis of the...
متن کاملMicrowave-induced thermoacoustic tomography: reconstruction by synthetic aperture.
We have applied the synthetic-aperture method to linear-scanning microwave-induced thermoacoustic tomography in biological tissues. A nonfocused ultrasonic transducer was used to receive thermoacoustic signals, to which the delay-and-sum algorithm was applied for image reconstruction. We greatly improved the lateral resolution of images and acquired a clear view of the circular boundaries of bu...
متن کاملMicrowave-induced thermoacoustic scanning CT for high-contrast and noninvasive breast cancer imaging.
A fast thermoacoustic computed tomography system with a multielement linear transducer array was developed to image biological tissues with circular scanning. The spatial resolution of the imaging system and the spectra of the thermoacoustic signals were analyzed. A modified integration backprojection algorithm using velocity potential was employed to recover the direct energy deposition distri...
متن کاملSignal processing in scanning thermoacoustic tomography in biological tissues.
Microwave-induced thermoacoustic tomography was explored to image biological tissues. Short microwave pulses irradiated tissues to generate acoustic waves by thermoelastic expansion. The microwave-induced thermoacoustic waves were detected with a focused ultrasonic transducer to obtain two-dimensional tomographic images of biological tissues. The dependence of the axial and the lateral resoluti...
متن کاملImaging of high-intensity focused ultrasound-induced lesions in soft biological tissue using thermoacoustic tomography.
An imaging technology, thermoacoustic tomograpy (TAT), was applied to the visualization of high-intensity focused ultrasound (HIFU)-induced lesions. A single, spherically focused ultrasonic transducer, operating at a central frequency of approximately 4 MHz, was used to generate a HIFU field in fresh porcine muscle. Microwave pulses from a 3-GHz microwave generator were then employed to generat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 28 9 شماره
صفحات -
تاریخ انتشار 2001