A microcomputer-based respiratory and activity recording system.
نویسندگان
چکیده
A respiratory and activity recording system has been developed for monitoring health conditions and living patterns, such as activity/rest time periods and general activity level. The system employs a piezoelectric sensor, a low-power operational amplifier, a low-power 8-bit microcomputer and a 512 KB EEPROM. The piezoelectric sensor, whose electrical polarization voltage is produced by mechanical strain, records body movements produced by respiration, heart pulse, walking and running. The high and low frequency components from the recorded body movements are discriminated by high and low pass filters. The high frequency components reflect the body movements produced by cardiac vibrations, walking and running activities. The low frequency components are mainly generated by respiration. The degree of activity is obtained by summing the high frequency components for 1 second. The microcomputer stores the obtained low frequency components and activity to the EEPROM at 0.2 second and 1 second intervals, respectively. After recording, these stored data are downloaded to a desktop computer. The computer then detects behavior patterns from the activity data and respiration from the low frequency components.
منابع مشابه
A Microcomputer-Based Simulator for Digital Control Systems
A microcomputer-based simulator for digital control systems is proposed. The proposed simulator is a hybrid system in which the plant is simulated by conventional method of analog computers and other parts of the system including generation of input signal is performed digitally, using a Z-80 based microcomputer. To overcome the difficulty of programming in assembly language, and at the same ti...
متن کاملTonic and reflex control of the cardio-respiratory system by neurons in the ventral medulla
To investigate the channels and neurotransmitters in the ventrolateral medulla (VLM) oblongata that are responsible for the maintenance of sympathetic tone and cardio-respiratory reflex regulation. Microinjections of excitant amino acid (glutamate, 100 nl, 100 mM), calcium channel blockers, agonists and antagonists were made throughout the VLM in anaesthetized rats. Arterial blood pressure, sym...
متن کاملTonic and reflex control of the cardio-respiratory system by neurons in the ventral medulla
To investigate the channels and neurotransmitters in the ventrolateral medulla (VLM) oblongata that are responsible for the maintenance of sympathetic tone and cardio-respiratory reflex regulation. Microinjections of excitant amino acid (glutamate, 100 nl, 100 mM), calcium channel blockers, agonists and antagonists were made throughout the VLM in anaesthetized rats. Arterial blood pressure, sym...
متن کاملA microcomputer interface for a digital audio processor-based data recording system.
An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collec...
متن کاملA Microcomputer-Based Conducting System
The subject of this paper is a portable, microcomputer-based performance system that we call the conduct system.1 This system was developed at the University of Toronto as part of the research of the Structured Sound Synthesis Project (SSSP) (Buxton, Fogels, Fedorkow and Smith 1978). The system, built around a microprocessor controlling a digital sound synthesizer, had its genesis in the earlie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomedical sciences instrumentation
دوره 38 شماره
صفحات -
تاریخ انتشار 2002