Experimental verification of Advanced Collapsed‐cone Engine for use with a multichannel vaginal cylinder applicator

نویسندگان

  • Brie Cawston‐Grant
  • Hali Morrison
  • Geetha Menon
  • Ron S Sloboda
چکیده

Model-based dose calculation algorithms have recently been incorporated into brachytherapy treatment planning systems, and their introduction requires critical evaluation before clinical implementation. Here, we present an experimental evaluation of Oncentra® Brachy Advanced Collapsed-cone Engine (ACE) for a multichannel vaginal cylinder (MCVC) applicator using radiochromic film. A uniform dose of 500 cGy was specified to the surface of the MCVC using the TG-43 dose formalism under two conditions: (a) with only the central channel loaded or (b) only the peripheral channels loaded. Film measurements were made at the applicator surface and compared to the doses calculated using TG-43, standard accuracy ACE (sACE), and high accuracy ACE (hACE). When the central channel of the applicator was used, the film measurements showed a dose increase of (11 ± 8)% (k = 2) above the two outer grooves on the applicator surface. This increase in dose was confirmed with the hACE calculations, but was not confirmed with the sACE calculations at the applicator surface. When the peripheral channels were used, a periodic azimuthal variation in measured dose was observed around the applicator. The sACE and hACE calculations confirmed this variation and agreed within 1% of each other at the applicator surface. Additionally for the film measurements with the central channel used, a baseline dose variation of (10 ± 4)% (k = 2) of the mean dose was observed azimuthally around the applicator surface, which can be explained by offset source positioning in the central channel.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning

PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...

متن کامل

First clinical implementation of the Capri applicator

This study was to assess the Capri applicator for patients with endometrial cancer undergoing high-radiation dose treatments following external-beam radiation therapy. The Capri applicator is an inflatable vaginal cylinder with multiple channels. It is used to tailor the dose distribution to an asymmetric vaginal disease, and better spare organs at risk. Five patients with high-risk endometrial...

متن کامل

SU-D-213AB-02: Optimal Design of Multichannel Vaginal Cylinder Applicators for High Dose Rate Brachytherapy.

PURPOSE To determine the optimal location of catheters in multichannel vaginal applicators to appropriately cover the vaginal cuff target and minimize dose to the organs at risk (OARs) and hot spots in the target. METHODS A new multichannel vaginal applicator with a diameter of 30 mmconsists of a single central catheter and an outer array of eight catheters. A total of 20 plans were generated...

متن کامل

Emission Reduction Strategies for Small Single Cylinder Diesel Engine Using Valve Timing and Swirl Ratio

Small diesel engines are widely used for commercial vehicle and passenger car applications due to their higher torque requirements, fuel economy, and better thermal efficiency. These engines are exposed to different operating and environmental conditions and hence emissions from these engines are erratic. Strategies are required to enhance performance and reduce engine-out emissions considering...

متن کامل

Dosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina

Currently, patients having cervical cancer with extension into the lower vagina are being treated with a combination of the Fletcher-Suit applicator, which treats the cervix, and a vaginal cylinder, which treats the lower vagina. With this method, patients receive two separate implants-a procedure that creates greater uncertainty in the dose distribution and unnecessary patient inconvenience. T...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2017