Hand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission.

نویسندگان

  • Randy W Loftus
  • Matthew K Muffly
  • Jeremiah R Brown
  • Michael L Beach
  • Matthew D Koff
  • Howard L Corwin
  • Stephen D Surgenor
  • Kathryn B Kirkland
  • Mark P Yeager
چکیده

BACKGROUND We have recently shown that intraoperative bacterial transmission to patient IV stopcock sets is associated with increased patient mortality. In this study, we hypothesized that bacterial contamination of anesthesia provider hands before patient contact is a risk factor for direct intraoperative bacterial transmission. METHODS Dartmouth-Hitchcock Medical Center is a tertiary care and level 1 trauma center with 400 inpatient beds and 28 operating suites. The first and second operative cases in each of 92 operating rooms were randomly selected for analysis. Eighty-two paired samples were analyzed. Ten pairs of cases were excluded because of broken or missing sampling protocol and lost samples. We identified cases of intraoperative bacterial transmission to the patient IV stopcock set and the anesthesia environment (adjustable pressure-limiting valve and agent dial) in each operating room pair by using a previously validated protocol. We then used biotype analysis to compare these transmitted organisms to those organisms isolated from the hands of anesthesia providers obtained before the start of each case. Provider-origin transmission was defined as potential pathogens isolated in the patient stopcock set or environment that had an identical biotype to the same organism isolated from hands of providers. We also assessed the efficacy of the current intraoperative cleaning protocol by evaluating isolated potential pathogens identified at the start of case 2. Poor intraoperative cleaning was defined as 1 or more potential pathogens found in the anesthesia environment at the start of case 2 that were not there at the beginning of case 1. We collected clinical and epidemiological data on all the cases to identify risk factors for contamination. RESULTS One hundred sixty-four cases (82 case pairs) were studied. We identified intraoperative bacterial transmission to the IV stopcock set in 11.5 % (19/164) of cases, 47% (9/19) of which were of provider origin. We identified intraoperative bacterial transmission to the anesthesia environment in 89% (146/164) of cases, 12% (17/146) of which were of provider origin. The number of rooms that an attending anesthesiologist supervised simultaneously, the age of the patient, and patient discharge from the operating room to an intensive care unit were independent predictors of bacterial transmission events not directly linked to providers. CONCLUSION The contaminated hands of anesthesia providers serve as a significant source of patient environmental and stopcock set contamination in the operating room. Additional sources of intraoperative bacterial transmission, including postoperative environmental cleaning practices, should be further studied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reduction in intraoperative bacterial contamination of peripheral intravenous tubing through the use of a novel device.

BACKGROUND Hand hygiene is a vital intervention to reduce health-care associated infections, but compliance remains low. The authors hypothesized that improvements in intraoperative hand hygiene compliance would reduce transmission of bacteria to surgical patients and reduce the incidence of postsurgical healthcare-associated infections. METHODS The authors performed a controlled before-and-a...

متن کامل

Securing the endotracheal tube with adhesive tape: an integrative literature review.

The practice of securing the endotracheal tube with adhesive tape appears to be benign. However, evidence-based research suggests it is a high-risk practice. Common elements for the taping practice include the tape, anesthesia gas machine, and anesthesia provider. Researchers have found that adhesive tape outside its original packaging became contaminated with pathogens. The bacteria found on t...

متن کامل

Reducing perioperative infection is as simple as washing your hands.

ANESTHESIOLOGISTS have long focused on patient safety, particularly in airway management, neurologic injury, and cardiac outcomes. More recently, anesthesiologists have begun to recognize their role in infection prevention as well. Healthcare-associated infections (HCAIs) increase morbidity and mortality, pain, cost, and duration of stay. The Centers for Disease Control and Prevention and the C...

متن کامل

Comparison of tracheal tube cuff inflation pressure among anesthesia team with different gradual level

Background & Objectives: Tracheal intubation is frequently performed in operating room. Over inflation of the endotracheal tube cuff is a risk factor for tracheal ischemia and subsequent complications. On the other hand inadequate cuff pressure increases the risk of aspiration of gastric contents. In this study, the endotracheal tube cuff pressure filled by the anesthesia team has been compared...

متن کامل

Quantifying the rambunctious journey of the anesthesia provider's hands during simulated, routine care.

BACKGROUND The role of anesthesia providers in dispersing potentially pathogenic material from one patient to another during intraoperative care needs further study. In this study we aimed (1) to quantify the dispersion of a surrogate pathogen from a simulated patient's mouth to the anesthesia workstation during routine anesthetic induction, (2) to test the hypothesis that there would be fewer ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 112 1  شماره 

صفحات  -

تاریخ انتشار 2011