Up to 16 years follow-up of aortic valve reconstruction with pericardium: a stentless readily available cheap valve?
نویسندگان
چکیده
OBJECTIVE There is lack of information regarding the long-term behavior of aortic valve reconstruction with pericardium (AoR). A 16-year follow-up is reported here. METHODS Between 1988 and 1995, 92 consecutive patients had AoR with bovine (Group I, n=27) or glutaraldehyde-treated autologous pericardium (Group II, n=65). The mean age was 30 years (range 12-68). There were 65% males, 92% in sinus rhythm, 84% had rheumatic etiology and 36% had 'other valve' surgery. Mitral valve replacement with a mechanical prosthesis is a contraindication to the operation. RESULTS Hospital mortality was 2%. The reconstructed aortic valve performed well with excellent hemodynamics. The mean follow-up interval was 10.5+/-4 years, range 9-16 years (longer for group I,12 versus 10 years) with 4% late deaths and seven patients lost to follow-up. Survival rate was 85+/-4%. There were no episodes of thromboembolism. Freedom from reoperation for the whole group was 68+/-5% at 10 years and 47+/-6% at 16 years. For group I, it was 68+/-9% at 10 years and 48+/-10% at 16 years, while for group II it was 72+/-6 and 45+/-8% at 10 and 15 years, respectively. Excluding endocarditis (one in group I and seven in group II) and 'other' reasons for reoperation (two in group I and three in group II), the freedom from structural valve degeneration (SVD) at 10 and 16 years was 78+/-1 and 55+/-10% for group I. For group II, it was 80+/-5% at 10 years and 58+/-9% at 15 years. The mean interval at which the valve degenerated was 8.8 years+/-3.6 and did not differ between the two groups. CONCLUSIONS AoR is feasible with good hemodynamics, low mortality and thromboembolic rate. Its behavior at 10 years is comparable to that of stentless aortic valve bioprosthesis. It can be performed with either xenopericardium or glutaraldehyde-treated autologous pericardium, but the latter has the advantage of being inexpensive and readily available.
منابع مشابه
Aortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...
متن کاملMagnetic resonance imaging of stentless xenografts for reconstruction of right ventricular outflow tract.
The objective was to overcome allograft shortage during the Ross operation; stentless xenografts were carefully evaluated for hemodynamic behavior and valve deterioration during medium term follow-up. Between January 10, 1994 and January 4, 1996 nine adult patients (age 31-51 years) underwent aortic valve replacement with an autologous pulmonary valve and right ventricular outflow tract reconst...
متن کاملFreestyle stentless bioprosthesis for aortic valve therapy: 17-year clinical results.
BACKGROUND Aortic valve replacement with stentless bioprostheses has been shown to produce lower aortic gradients than stented bioprostheses, thus facilitating left ventricular mass regression and preventing heart failure. We sought to determine the long-term results of stentless biological aortic valve replacement over a 17-year follow-up. METHODS Between 1996 and 2012, 2551 patients underwe...
متن کاملHemodynamic behavior of stentless aortic valves in long term follow-up
OBJECTIVES Stentless aortic valve replacements show improved hemodynamics due to larger orifice area and lower transvalvular gradients in short and mid-term follow-up. Hemodynamic long-term behavior and the adaptation of the left ventricle as well as valve-durability in patients aged ≤60 years remains unclear. METHODS 7 to 16 years after aortic valve replacement, 54 patients (mean age at oper...
متن کاملStructural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.
BACKGROUND Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 28 2 شماره
صفحات -
تاریخ انتشار 2005