An Attempt of Subjective Refraction Test Maintaining Everyday Pupil Diameter Using Ground Glass Lens
نویسندگان
چکیده
Purpose: To investigated the effects of pupil dilation on subjective refraction by using ground glass lens. Methods: Forty-two subjects (22.1 ± 1.2 years) participated in the study. We measured the change in pupil diameter during binocular and monocular vision (using an occluder and a ground glass lens). And we conducted subjective refraction test using an occluder and a ground glass lens. Paired t-test was used for statistical analysis of pupil diameter and subjective refraction. Pearson’s rank correlation test was performed to assess the relationship between subjective refraction change and pupil diameter change. The p-value of < 0.01 was considered statistically significant. Results: The average pupil diameter measured before and after covering with an occluder was 4.35 ± 0.55 mm and 5.77 ± 0.75 mm (P < 0.0001). The average pupil diameter measured before and after covering with ground glass lens was 4.38 ± 0.65 mm and 4.39 ± 0.68 mm (P = 0.78). The average spherical equivalent subjective refraction using an occluder and a ground glass lens was -3.89 ± 2.15D, -3.67 ± 2.02D. Using an occluder resulted in significantly more myopia than using a ground glass lens (P < 0.0001). The bigger the change in pupil diameter, the bigger was the change in subjective refraction (P = 0.0005; R2 = 0.25). Conclusions: Our results indicate using a ground glass lens is effective method for measuring the exact refraction value.
منابع مشابه
Peep Into Visual Acuity Chart Through an Opening: A New Concept of Binocular Open-view Visual Acuity Test.
To the Editor: For some time we have used a clinical visual acuity test (subjective refraction) only for monocular testing. However, we believe that visual acuity measurements need to be performed under binocular open-view conditions as close to natural viewing conditions as possible. Subjective refractions without cycloplegia were examined with the Occlupad (Japan Focus Co., Ltd., Tokyo, Japan...
متن کاملAccommodation and age-dependent eye model based on in vivo measurements.
PURPOSE To develop a flexible model of the average eye that incorporates changes with age and accommodation in all optical parameters, including entrance pupil diameter, under photopic, natural, environmental conditions. METHODS We collated retrospective in vivo measurements of all optical parameters, including entrance pupil diameter. Ray-tracing was used to calculate the wavefront aberratio...
متن کاملThe Boston keratoprosthesis provides a wide depth of focus.
PURPOSE To measure the through-focus curve for eyes implanted with a type 1 Boston keratoprosthesis (KPro) and compare it to that of pseudophakic controls with fixed pupil sizes. The results should assist in evaluating postoperative visual quality after surgery. They should also help to determine the necessary KPro inventories in terms of refractive power steps. METHODS Autorefraction and man...
متن کاملThe Effects of Age, Refractive Status, and Luminance on Pupil Size
PURPOSE Pupil size is critical for optimal performance of presbyopic contact lenses. Although the effect of luminance is well known, little information is available regarding other contributing factors such as aging and refractive status. METHODS The cohort population comprised 304 patients (127 male, 177 female) aged 18 to 78 years. Pupils were photographed at three controlled luminance leve...
متن کاملWearable telescopic contact lens.
We describe the design, fabrication, and testing of a 1.6 mm thick scleral contact lens providing both 1× and 2.8× magnified vision paths, intended for use as a switchable eye-borne telescopic low-vision aid. The F/9.7 telescopic vision path uses an 8.2 mm diameter annular entrance pupil and 4 internal reflections in a polymethyl methacrylate precision optic. This gas-impermeable insert is cont...
متن کامل